  Use only new or clean PVC pipe fi

6

 ttings.

   Wrap male pipe threads with a sufficient number of layers of Tefl on tape. 

Cover entire thread portion.

  Do not overtighten or tighten past thread stop in pump port.

   If leaks occur, remove pipe, clean off old tape, wrap as previously with one 

to two additional layers of tape and remake the connection.

Piping

Support all piping connected to the pump.

   Use at least 2” (50mm) PVC pipe. Increase size if a long run is needed.
   To avoid stress on the pump, support both suction and discharge pipes 

independently.

  Place these supports as close to the pump as possible.

   To avoid a strain left by a gap at the last connection, start all piping at the pump 

and run pipe away from the pump.

  Never use a suction pipe smaller than pump suction connections (2”/50mm).

  To avoid airlocking, slope suction pipe slightly upward toward the pump.
   Do not use an elbow near the suction port of the pump. Use a straight length of 

pipe into the suction port.

To prevent flooding when removing pump for service, all fl ooded suction
systems must have shut-off valves in suction and discharge pipes.

Fittings

Teflon Taping Instructions

Fittings restrict flow; for best efficiency use fewest possible fittings. Avoid
fittings which could cause an air trap.

Pool Outlets

Use only non-entrapping suction fitting or double suction conforming with
the AS1926.3 standard.

L300216_SilentFlo_OM_2012

Monday, 17 December 2012 1:32:22 PM

Summary of Contents for silentflo

Page 1: ...should contact the distributor manufacturer for the correct advice before proceeding For the Installation Operation and Service of SilentFlo Pool Pump The pump must be supplied from a circuit with the...

Page 2: ...g 4 Pump Mount 5 Tefon Taping Instructions 6 Fittings 6 Pool Outlets 6 Entrapment Protection 7 Testing and Certifcation 7 Outlets per Pump 7 Water Velocity 7 Electrical 8 Operation 9 Priming Pump 10 S...

Page 3: ...n to suit 50mm I D PVC pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm I D PVC pipe to AS NZS 1477 Max Working Pressure 260 kPa Water Temperature Range 5 C 38 C IP Rating IPX5 Elect...

Page 4: ...n cause explosion Ensure all air is out of the system before operating or testing equipment Silentflo is electrically connected Ensure that it is isolated from electrical supply during installation an...

Page 5: ...re it is ready for operation Remove trap lid and retighten hand tight only Fire and burn hazard Modern motors run at high temperatures To reduce risk of re do not allow leaves debris or foreign matter...

Page 6: ...asteners 3 Allow pump suction inlet height to be as far below water level as possible 4 Allow use of short direct suction pipe to reduce friction losses 5 Allow for shut off valves in suction and disc...

Page 7: ...p as possible To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump Never use a suction pipe smaller than pump suction connections 2 50mm...

Page 8: ...Outlets Per Pump Provide at least two hydraulically balanced main drains with covers for each swimming pool pump suction line The centres of the main drains suction ttings must be at least 800mm apart...

Page 9: ...al system Do not use extension leads as they are unsafe in and around the Pool Zone Incorrect voltage can cause re or seriously damage pump and voids warranty Voltage at pump must not be more than 6 a...

Page 10: ...AYS have close adult supervision Pump suction is hazardous and can trap and drown or disembowel bathers Do not use or operate pump pool spas if a suction outlet cover is missing broken or loose Follow...

Page 11: ...equipment O ring contains a permanent internal lubricant If the o ring needs replacement insist on genuine Onga service parts Clean and inspect o ring reinstall on trap Replace trap lid turn clockwis...

Page 12: ...t and clean Ensure all holes in basket are clear ush basket with water and replace in trap with large opening at pipe connection port between ribs provided If basket is replaced backwards the cover wi...

Page 13: ...from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer vert...

Page 14: ...appliance that is known to work to check power outlet Blown fuse Circuit breaker Check and call electrician if necessary Motor burnt out due to voltage spike or fooded by water The motor may need repl...

Page 15: ...EMBLY 19 BARREL UNION KIT INCLUDES 19a 19b 19c x2 19a COLLAR UNION 2 SLIP 19b COLLAR UNION 2 19c ORING Collar Union 20 BASE 21 SCREW 5 16 14 x 1 22 MOTOR PAD BASE KIT INCLUDES 19 20 21 1 MOTOR SF55010...

Page 16: ...has been made to publish the correct details in this data sheet No responsibility will be taken for errors omissions or changes in product specifications Pentair Water reserves the right to change spe...