Hazardous voltage.
Can shock, burn or
cause death.

8

WARNING

Electrical

Electrical installation shall be in accordance with the national wiring rules (AS/NZS 
3000) taking into account its ratings (Class I, IPX5). The pump is supplied with a 
standard Australian 10 amp plug and 2 metres of cord. Select the correct Pool Zone 
for installation.

Using the tapped hole terminal and tin plated copper lug connect the equipotential 
bonding conductor to the pump if required. The terminal is on the motor side of the 
fl ange. Remove paint from the terminal surface and use M5x12 zinc plated screw with 
lock washer or similar to secure the termination.

An RCD with maximum rated residual current of 30mA is required for the power supply 
to the pump. Additionally, if a suitable socket outlet is not available a weatherproof 
socket must be installed by an electrician in a suitable location. RCD tripping indicates 
an electrical problem. If RCD trips and will not reset have a qualifi ed electrician inspect 
and repair electrical system.

Do not use extension leads as they are unsafe in and around the Pool Zone.

Incorrect voltage can cause fire or seriously damage pump and voids warranty.

Voltage at pump must not be more than 6% above or 
10% below motor nameplate rated voltage or pump 
may overheat, causing overload tripping and reduced 
component life. If voltage is less than 90% or more than 
106% of rated voltage when pump is running at full load, 
consult the power company.

To avoid dangerous or fatal electrical shock, turn OFF 
power to pump and remove plug from outlet before 
working on electrical connections.

The power supply cord has a type ‘Y’ attachment and if 
service is required to the power cord, it must be replaced 
with the specialised power cord assembly by Pentair 
Water service agent or similarly qualifi ed personnel in 
order to avoid a hazard. Warranty is void if unauthorised 
modifications are made to any component.

No valves between Tee 

and Main Drains

Valves OK between 

pump and Tee

Suction Outlet

(Main Drain)

Suction Outlet

(Main Drain)

Certified Anti-entrapment 

Cover or Suction Fitting, 

screw fastened to Main

 

Drain Sump

Certified Anti-entrapment 

Cover or Suction Fitting, 

screw fastened to Main

 

Drain Sump

Pump

800mm

L300216_SilentFlo_OM_2012

Monday, 17 December 2012 1:32:22 PM

Summary of Contents for silentflo

Page 1: ...should contact the distributor manufacturer for the correct advice before proceeding For the Installation Operation and Service of SilentFlo Pool Pump The pump must be supplied from a circuit with the...

Page 2: ...g 4 Pump Mount 5 Tefon Taping Instructions 6 Fittings 6 Pool Outlets 6 Entrapment Protection 7 Testing and Certifcation 7 Outlets per Pump 7 Water Velocity 7 Electrical 8 Operation 9 Priming Pump 10 S...

Page 3: ...n to suit 50mm I D PVC pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm I D PVC pipe to AS NZS 1477 Max Working Pressure 260 kPa Water Temperature Range 5 C 38 C IP Rating IPX5 Elect...

Page 4: ...n cause explosion Ensure all air is out of the system before operating or testing equipment Silentflo is electrically connected Ensure that it is isolated from electrical supply during installation an...

Page 5: ...re it is ready for operation Remove trap lid and retighten hand tight only Fire and burn hazard Modern motors run at high temperatures To reduce risk of re do not allow leaves debris or foreign matter...

Page 6: ...asteners 3 Allow pump suction inlet height to be as far below water level as possible 4 Allow use of short direct suction pipe to reduce friction losses 5 Allow for shut off valves in suction and disc...

Page 7: ...p as possible To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump Never use a suction pipe smaller than pump suction connections 2 50mm...

Page 8: ...Outlets Per Pump Provide at least two hydraulically balanced main drains with covers for each swimming pool pump suction line The centres of the main drains suction ttings must be at least 800mm apart...

Page 9: ...al system Do not use extension leads as they are unsafe in and around the Pool Zone Incorrect voltage can cause re or seriously damage pump and voids warranty Voltage at pump must not be more than 6 a...

Page 10: ...AYS have close adult supervision Pump suction is hazardous and can trap and drown or disembowel bathers Do not use or operate pump pool spas if a suction outlet cover is missing broken or loose Follow...

Page 11: ...equipment O ring contains a permanent internal lubricant If the o ring needs replacement insist on genuine Onga service parts Clean and inspect o ring reinstall on trap Replace trap lid turn clockwis...

Page 12: ...t and clean Ensure all holes in basket are clear ush basket with water and replace in trap with large opening at pipe connection port between ribs provided If basket is replaced backwards the cover wi...

Page 13: ...from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer vert...

Page 14: ...appliance that is known to work to check power outlet Blown fuse Circuit breaker Check and call electrician if necessary Motor burnt out due to voltage spike or fooded by water The motor may need repl...

Page 15: ...EMBLY 19 BARREL UNION KIT INCLUDES 19a 19b 19c x2 19a COLLAR UNION 2 SLIP 19b COLLAR UNION 2 19c ORING Collar Union 20 BASE 21 SCREW 5 16 14 x 1 22 MOTOR PAD BASE KIT INCLUDES 19 20 21 1 MOTOR SF55010...

Page 16: ...has been made to publish the correct details in this data sheet No responsibility will be taken for errors omissions or changes in product specifications Pentair Water reserves the right to change spe...

Reviews: