Incorrectly installed or tested equipment may fail, causing severe injury 
or property damage.

Read the following instructions in this owner’s manual 
when installing and operating equipment. Have a trained 
pool professional perform all pressure tests.

1. Do not connect system to high pressure or mains 

water system.

2. Use equipment only in a swimming pool or spa pool 

installation.

3. Install pump with at least 2 hydraulically balanced 

main drains equipped with correctly installed, screw - 
fastened, antientrapment certified covers according 
to local regulations.

4. Trapped air in system can cause explosion.

Ensure all air is out of the system before operating or 
testing equipment.

Silentflo is electrically connected. Ensure that it is isolated 
from electrical supply during installation and any subsequent 
service work.

The pump should be installed and serviced by a suitably 
qualified person in order to avoid hazard.

These instructions are a guide only. Should you the installer or 
owner of the product be unfamiliar with the correct installation 
or operation of this product you should contact a suitably 
qualified person for advice.

Freezing conditions will damage the unit, as water expands as 
it freezes. Ensure that Silentflo is located so that it is not prone 
to freezing, or ensure that the product is disconnected and 
dried of water during cold conditions.

Installation

L300216_SilentFlo_OM_2012

Monday, 17 December 2012 1:32:22 PM

Summary of Contents for silentflo

Page 1: ...should contact the distributor manufacturer for the correct advice before proceeding For the Installation Operation and Service of SilentFlo Pool Pump The pump must be supplied from a circuit with the...

Page 2: ...g 4 Pump Mount 5 Tefon Taping Instructions 6 Fittings 6 Pool Outlets 6 Entrapment Protection 7 Testing and Certifcation 7 Outlets per Pump 7 Water Velocity 7 Electrical 8 Operation 9 Priming Pump 10 S...

Page 3: ...n to suit 50mm I D PVC pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm I D PVC pipe to AS NZS 1477 Max Working Pressure 260 kPa Water Temperature Range 5 C 38 C IP Rating IPX5 Elect...

Page 4: ...n cause explosion Ensure all air is out of the system before operating or testing equipment Silentflo is electrically connected Ensure that it is isolated from electrical supply during installation an...

Page 5: ...re it is ready for operation Remove trap lid and retighten hand tight only Fire and burn hazard Modern motors run at high temperatures To reduce risk of re do not allow leaves debris or foreign matter...

Page 6: ...asteners 3 Allow pump suction inlet height to be as far below water level as possible 4 Allow use of short direct suction pipe to reduce friction losses 5 Allow for shut off valves in suction and disc...

Page 7: ...p as possible To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump Never use a suction pipe smaller than pump suction connections 2 50mm...

Page 8: ...Outlets Per Pump Provide at least two hydraulically balanced main drains with covers for each swimming pool pump suction line The centres of the main drains suction ttings must be at least 800mm apart...

Page 9: ...al system Do not use extension leads as they are unsafe in and around the Pool Zone Incorrect voltage can cause re or seriously damage pump and voids warranty Voltage at pump must not be more than 6 a...

Page 10: ...AYS have close adult supervision Pump suction is hazardous and can trap and drown or disembowel bathers Do not use or operate pump pool spas if a suction outlet cover is missing broken or loose Follow...

Page 11: ...equipment O ring contains a permanent internal lubricant If the o ring needs replacement insist on genuine Onga service parts Clean and inspect o ring reinstall on trap Replace trap lid turn clockwis...

Page 12: ...t and clean Ensure all holes in basket are clear ush basket with water and replace in trap with large opening at pipe connection port between ribs provided If basket is replaced backwards the cover wi...

Page 13: ...from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer vert...

Page 14: ...appliance that is known to work to check power outlet Blown fuse Circuit breaker Check and call electrician if necessary Motor burnt out due to voltage spike or fooded by water The motor may need repl...

Page 15: ...EMBLY 19 BARREL UNION KIT INCLUDES 19a 19b 19c x2 19a COLLAR UNION 2 SLIP 19b COLLAR UNION 2 19c ORING Collar Union 20 BASE 21 SCREW 5 16 14 x 1 22 MOTOR PAD BASE KIT INCLUDES 19 20 21 1 MOTOR SF55010...

Page 16: ...has been made to publish the correct details in this data sheet No responsibility will be taken for errors omissions or changes in product specifications Pentair Water reserves the right to change spe...

Reviews: