FR01 end cycle
alarm.
Micro-switch support damaged.
Open the controller box and check the
integrity of the plastic parts holding
the micro-switch.
Cam not fixed.
Check if the cam is properly fixed by
the circlip.
Micro-switch stick damaged.
Check if the metal stick which closes
the micro-switch is damaged.
Micro-switch damaged.
Dismount the micro-switch and try to
actuate it manually. If the controller
goes back in service the micro-switch
is working, if this is the case check for
mechanical problems.
If the controller does not go back in
service, the micro-switch is damaged
or there is a wiring problem.
Wiring problem.
Using the electrical diagrams check if
the wiring of the micro-switch is
properly done.
Check the integrity of the harness.
Motor problem.
Check if the motor is running. Check
motor wiring and the harnesses
integrity.
Check if motor shaft is linked to pinion
gear and torque transfer to pinion
during motor rotation.
The controller
displays wrong
parameters.
The controller is out of program.
Dismount the box and press the reset
hardware button. If this does not solve
the problem change the electronic
board.
The controller is
blocked, whatever
button is pressed
it does not gives
feedback on the
display.
Controller
displays ErEE or
ErES.
EEprom parameters reading error/
EEprom statistics reading error.
If these parameters are displayed
continuously, the board is damaged.
The controller
does not start
regeneration.
Inhibit signal active.
Check if there is a shortcut between
the inhibit terminal ports.
Bad programming.
Check if the controller is well
programmed based on the system
configuration.
Issue
Cause
Reset and recovery
Summary of Contents for SIATA V132-SFE-EV-VIRIDION
Page 1: ...SIATA V132 SFE EV VIRIDION INSTALLER MANUAL WATER PURIFICATION...
Page 77: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 77 110...
Page 79: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 79 110...
Page 81: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 81 110...
Page 83: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 83 110...
Page 85: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 85 110...
Page 87: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 87 110...
Page 89: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 89 110...
Page 91: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 91 110...
Page 110: ...www pentairaquaeurope com...