Installer Manual Siata V132-SFE-EV-VIRIDION - Installation
38 / 110
Ref. MKT-IM-009 / C - 08.06.2018
5.3.5. Mechanical
•
Do not use PTFE (plumber’s tape) lubricants such as vaseline, oils, or hydrocarbon-based
lubricants. Use only 100% silicone lubricants;
•
all plastic connections should be hand tightened. PTFE (plumber’s tape) may be used on
connections that do not use an o-ring seal. Do not use pliers or pipe wrenches;
•
all plumbing must be completed according to local codes;
•
soldering near the drain line should be done before connecting the drain line to the valve.
Excessive heat will cause interior damage to the valve;
•
observe the drain line requirements:
maximum 1 m high at 2 bars inlet pressure. Add 50 cm for each additional 1 bar inlet pressure;
•
do not use lead-based solder for sweat solder connections;
•
do not support the weight of the system on the valve fittings, plumbing, or the bypass;
•
it is not recommended to use sealants on the threads. Use PTFE (plumber’s tape) on the threads
of the 2" BSP or in any other threaded connection in the valve;
•
the installation of a prefilter is always recommended (100μ nominal).
5.3.6. Integration constraints
The location of a water treatment system is important. The following conditions are required:
•
level platform or floor;
•
room to access equipment for maintenance and adding brine (salt) to tank;
•
total minimum pipe run to water heater of 3 m to prevent backup of hot water into system;
•
always install a check valve before water heater to protect the softener from hot water return;
•
local drain for discharge as close as possible;
•
water line connections with shut off or bypass valves;
•
must meet any local and state codes for the installation site;
•
the valve is designed for minor plumbing misalignments. Do not support the weight of the
system on the plumbing;
•
make sure all soldered pipes are fully cooled before attaching plastic valves to the plumbing;
•
the existing plumbing should be in a good condition and free from limescale. If in doubt, replace
it. The installation of a pre-filter is always advised.
Summary of Contents for SIATA V132-SFE-EV-VIRIDION
Page 1: ...SIATA V132 SFE EV VIRIDION INSTALLER MANUAL WATER PURIFICATION...
Page 77: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 77 110...
Page 79: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 79 110...
Page 81: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 81 110...
Page 83: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 83 110...
Page 85: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 85 110...
Page 87: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 87 110...
Page 89: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 89 110...
Page 91: ...Installer Manual Siata V132 SFE EV VIRIDION Maintenance Ref MKT IM 009 C 08 06 2018 91 110...
Page 110: ...www pentairaquaeurope com...