MOUNTING
TOOLS REQUIRED FOR INSTALLATION:
• #2 Phillips screwdriver
• 6.5 mm slotted screwdriver
• 13 mm wrench or socket
EXTERNAL MOUNTING
1. Using the mounting gasket kit provided with the unit, install gasket to the air conditioner, see Figure
1.
2. Screw the supplied grub screws into the blind nuts on the rear of the unit, see Figure 2.
3. Secure the unit to the enclosure using the supplied washers and nuts. Use caution to avoid damaging
the gasket while positioning the unit.
Figure 1
Figure 2
PARTIAL RECESSED MOUNTING (NOT APPLICABLE TO 300W UNIT)
1. Carefully remove the louvered grille, and where applicable, remove the center panel from the
enclosure by pulling forwards. See Figure 3 on page 9.
2. Carefully disconnect the connectors from the rear of the smart controller.
3. Remove the two front screws.
4. Remove the four nuts on the front panel and pull the panel assembly forward approximately 5 cm.
See Figure 4 on page 9.
5. Disconnect the fan electrical connection.
6. Remove the front panel.
7. Remove the four standoffs, leaving the grub screws in place.
8. Push the rear enclosure half into the mounting cutout and secure it with the four standoffs. See
Figure 5 on page 9.
9. Push the smart controller cables through the rectangular hole in the front panel.
10. Reconnect the fan electrical connector.
11. Mount the front panel using the nuts removed in step 4.
12. Install two front screws.
13. Carefully reconnect the smart controller connectors .
14. Push the louvered grille and, where applicable, the center panel, onto the front panel. See Figure 6
on page 9.
Summary of Contents for S06
Page 9: ... 2015 Pentair Equipment Protection 89116616 9 Figure 3 Figure 4 Figure 5 Figure 6 ...
Page 17: ... 2015 Pentair Equipment Protection 89116616 17 S06 WIRE DIAGRAM 300 500W ...
Page 24: ... 2015 Pentair Equipment Protection 89116616 24 1500W 115V 1500W 230V ...
Page 25: ... 2015 Pentair Equipment Protection 89116616 25 1500W 460V 89107589 REV G ...
Page 26: ... 2015 Pentair Equipment Protection 89116616 26 S10 WIRE DIAGRAMS 1000W 115V 230V ...
Page 27: ... 2015 Pentair Equipment Protection 89116616 27 1000W 460V ...
Page 28: ... 2015 Pentair Equipment Protection 89116616 28 1500W 115V ...
Page 29: ... 2015 Pentair Equipment Protection 89116616 29 1500W 230V ...
Page 30: ... 2015 Pentair Equipment Protection 89116616 30 1500W 460V 89107588 REV H ...
Page 38: ... 2015 Pentair Equipment Protection 89116616 38 2000W 460V 89107589 REV G 2500W 115V ...
Page 39: ... 2015 Pentair Equipment Protection 89116616 39 2500W 230V 2500W 460V 89107593 REV G ...
Page 40: ... 2015 Pentair Equipment Protection 89116616 40 4000W 460V ...
Page 41: ... 2015 Pentair Equipment Protection 89116616 41 S16 WIRE DIAGRAMS 2000W 115V ...
Page 42: ... 2015 Pentair Equipment Protection 89116616 42 2000W 230V ...
Page 43: ... 2015 Pentair Equipment Protection 89116616 43 2000W 460V 89107588 REV H ...
Page 44: ... 2015 Pentair Equipment Protection 89116616 44 2500W 115V ...
Page 45: ... 2015 Pentair Equipment Protection 89116616 45 2500W 230V ...
Page 46: ... 2015 Pentair Equipment Protection 89116616 46 2500W 460V 89107592 REV H ...
Page 47: ... 2015 Pentair Equipment Protection 89116616 47 4000W 460V ...
Page 49: ... 2015 Pentair Equipment Protection 89116616 49 4000W W DKE dKZ ϰϲϬs KE zͿ Ͳ W d WKZd ...
Page 58: ... 2015 Pentair Equipment Protection 89116616 58 NOTES ...
Page 63: ... 2015 Pentair Equipment Protection 89116616 63 NOTES ...