14
HYP1100 (04-08-21)
CONTROL OVERVIEW
HOME
1. Section On/Off buttons
These are the controls for individual ProStop-E valves/
sections. The sections can be toggled on/off from either
direction using the on/off buttons.
2. Section Indicators
Green indicates a section is turned on, red indicates that
the section is turned off. When virtual sections are used,
a rectangular box will appear with the section numbers.
The number of sections (and corresponding widths) is
specified in Ch. 1 Setup/ Implement.
3. Information Display
This display shows Rate/Minute as default. The units
shown at upper right corner reflect the default unit
of measure. This window can also be reconfigured by
selecting the window and choosing another option.
4. Information Display
This display shows Pressure as default. The units shown
at upper right corner reflect the default unit of measure.
This window can also be reconfigured by selecting the
window and choosing another option.
5. Information Display
This display shows Volume as default. The units shown
at upper right corner reflect the default unit of measure.
This window can also be reconfigured by selecting the
window and choosing another option.
6. Target Rate
This display shows the programmed Target Rate of the
system. The target rate can be incrementally adjusted
using Increase/Decrease on-screen keys. The setting for
Target Rate is located in Ch.1 Setup/ Operation.
7. Actual Applied Rate
This display shows the actual applied Rate of the system.
If the Actual Applied Rate is different than the Target
Rate, an alarm will pop-up to notify the operator. The Rate
Alarm Threshold setting is located in Ch.1 Setup/Alarms
tab.
8. Information Display
This display shows Area as default. The units shown at
upper right corner reflect the default unit of measure.
This window can also be reconfigured by selecting the
window and choosing another option.
9. Increase/Decrease
These on-screen keys increase (+) or decrease (-) the
overall rate of application. If channel is set to Automatic,
the Increase/ Decrease buttons will affect the Target
Rate in preset increments. The increment of change
per key press is defined in Ch.1 Setup/ Operation tab
(default=1). When channel is set to Manual, the Increase/
Decrease buttons change the Actual rate of application
based on the length of button is held down.
1
2
3
4
5
11
6
7
8
14
15
16
17
18
19
10
12
13
9
Summary of Contents for PROSTOP-E
Page 41: ...41 HYP1100 04 08 21 PART NUMBER 2520 0258 WIRINGDIAGRAMS...
Page 42: ...42 HYP1100 04 08 21 PART NUMBER 2520 0250 PART NUMBER 2520 0251 WIRINGDIAGRAMS...
Page 43: ...43 HYP1100 04 08 21 PART NUMBER 2520 0252 PART NUMBER 2520 0253 WIRINGDIAGRAMS...
Page 44: ...44 HYP1100 04 08 21 PART NUMBER 2520 0237 WIRINGDIAGRAMS...