49
SunTouch Pool and Spa Control System Installation and User’s Guide
Installing Conduit and Wire to the SunTouch Power Center
•
Use No. 14 (min.) to No. 6 (max.) AWG for power relay circuits depending on the power
requirement. Be sure to follow all regulation safety codes for the number and size of conductors that
can be installed in various sizes of conduit.
•
Supply circuit must be protected by suitable circuit breaker.
•
To avoid obstruction into the SunTouch power center, when using electrical conduit complete the
installation of the conduit before concrete is poured. Also, underground conduit should be positioned
in well compacted soil. Ensure that all conduit joints are well sealed and watertight.
WARNING!
When installing and using this electrical equipment, basic safety precautions should
always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS. READ AND FOLLOW ALL
INSTRUCTIONS
.
•
DANGER! RISK OF ELECTRIC SHOCK, WHICH CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation of service, ensure that all power to the circuit supplying power to the
system is disconnected/turned off at the circuit breaker.
•
Grounding (earth bonding) is required. The SunTouch Power Center should be installed by a
qualified
professional.
•
Read Safety Precautions and Important Instructions (page iv and v). Before attempting any
electrical wiring, be sure to read and follow Safety Instructions. Wiring should only be
performed by a qualified professional.
TO AVOID AN ELECTRICAL HAZARD -
Do not connect the power source conductors to the
SunTouch power center until all electrical connections for all equipment (heaters, pumps, motorized
valves, and lights etc.) have been completed.
•
Follow manufactures instructions when installing and testing of ground fault circuit breakers (GFCB) and
interrupters (GFCI).
•
For the main AC power conduit, it is recommended to use the 3/4" conduit knockout located directly under
the enclosure.
•
Use the 1” grommet low voltage raceway opening located on the underside of the SunTouch power center
for the temperature sensor wires. For connection information (see page 51).
CAUTION
All of the electrical wiring methods and materials used to complete the electrical installation of
the SunTouch Pool/Spa Control System must be in accordance with the National Electrical Code or the
Canadian Electric Code, as well as any local electrical codes in effect at the time of installation.
CAUTION
All electrical materials used for the SunTouch installation must be accomplished by, or be
under the direct supervision of a qualified electrician.
Summary of Contents for Pool and Spa Control System SunTouch
Page 44: ...36 SunTouch Pool and Spa Control System Installation and User s Guide Blank Page...
Page 80: ...72 SunTouch Pool and Spa Control System Installation and User s Guide Blank Page...
Page 85: ...77 SunTouch Pool and Spa Control System Installation and User s Guide Notes...
Page 86: ...78 SunTouch Pool and Spa Control System Installation and User s Guide Notes...
Page 87: ......
Page 88: ...P N 520785 Rev A 520785...