33
SunTouch Pool and Spa Control System Installation and User’s Guide
SunTouch Main Status Screen (Pool/Spa Mode - Single Body System)
Use the SunTouch display to view the daily operations of your spa or pool. Using the UP arrow button
(HI-TEMP) to manually switch the filter pump on and off and activate the heater. LOW temperature control
can also be assigned to the UP arrow button. The “HIGH” and “LOW” circuit can be programmed to run at a
specific time and heat setting. These circuits are assigned in the “Circuit Functions” menu (see page 26).
Before using SunTouch to operate a single body system (pool only or spa only), familiarize yourself with the
status screen and control buttons.
AIR:
Displays the outside air
temperature via the air sensor
located near the pool area. This screen toggles between
the “Pool” or “Spa” display (see below). To display the air
temperature setting, the air sensor must be enabled
(see “Advanced” menu on page 24). Degree units are
displayed in either Fahrenheit or Celsius. If the top
display line displays “SunTouch”, it indicates no spa or
pool function is active and the air sensor is not enabled.
HIGH:
When the Up arrow button is
pressed or this circuit is scheduled
to operate, the “HIGH” filter pump circuit is switched on
and current water temperature settings are displayed
with the heat source being used. “HIGH” and “LOW” are
displayed alternatively if both circuits are active.
LOW:
When the Down arrow button
is pressed or this circuit is
scheduled to operate, the “LOW” filter pump circuit is
switched on and current water temperature settings are
displayed with the type heat source being used. “HIGH”
and “LOW” are displayed alternatively if both circuits are
active.
HIGH 75°F / 85°F
11:51AM HEATER
HI-TEMP/LO-TEMP button:
Turn
heater and filter pump on or off.
To activate the heater when this
button is pressed, first select heat
source in the “Heat 2/13” menu
(page 14). To manually switch on
or off the heater, use “Manual
Heat” in the “Heat 2/13” menu.
The heat temperature settings
are displayed on the main
screen. This button can also be
assigned for LOW temperature
control (see page 34).
AUX 1:
When this button is
pressed, the circuit relay con-
nected to AUX 1 is switched on
and the number 1 is displayed on
the lower right-side of the screen.
AUX 1 can also be switched on
and off manually from the “Circuit
On/Off” menu (see page 13).
Auxiliary functions are assign in
the “Circ. Function” menu see
page 26). AUX 1 can be assign to
operate accessory equipment
such as pool and spa lights.
HEATER:
Displays the heat source (
Heater, Solar Prf., Solar
)
as specified in the “Heat” menu settings (see page 14). If heat is
enabled, when the pool filter pump is switch on, the heat source
is displayed.
75° F / 85° F:
Displays the actual spa or pool water temperature
(75° F) and the set point temperature (85° F) as set in the
“Heater” menu (see page 14). To adjust set temperature setting
use the (-) TEMP and (+) TEMP buttons.
Time:
Displays the SunTouch system time as set in the “Clock”
menu setting (see page 19).
AUX 1 2 3:
Displays AUX 1, 2, 3 (lower line)
when these auxiliary relay circuits are
switched on. Press the AUX 1 (
1
) button to manually switch
auxiliary 1 on or off. AUX 2, and AUX 3 can be switch on and off
manually from the “Circuit On/Off” menu (page 13). Auxiliary
functions are assign in the “Circ. Function” menu (page 26).
AUX D:
“D” indicates the selected circuit
(AUX 1,2,3) is in “delay” mode. For
example, if AUX 2 is assigned to a cleaner, when the auxiliary
circuit 2 is switched on via the “Circuit On/Off” menu setting, this
will force the filter pump on for five (5) minutes before the
cleaner pump switches on. See “Circuit Functions Menu” (page
26) for more information.
HIGH 75°F / 85°F
11:51AM HEATER
LOW 75°F / 85°F
11:51AM HEATER
AIR 77°F FRZ
11: 51AM AUX 1
FRZ:
Indicates the air sensor is
connected and enabled, and
“Freeze Protection” is active (see page 26).
AIR 77°F FRZ
11: 51AM AUX 1
AIR 77°F
11: 51AM AUX D
Lower current set point
temperature setting
Raise current set point
temperature setting
AIR 77°F
11: 51AM AUX 123
Summary of Contents for Pool and Spa Control System SunTouch
Page 44: ...36 SunTouch Pool and Spa Control System Installation and User s Guide Blank Page...
Page 80: ...72 SunTouch Pool and Spa Control System Installation and User s Guide Blank Page...
Page 85: ...77 SunTouch Pool and Spa Control System Installation and User s Guide Notes...
Page 86: ...78 SunTouch Pool and Spa Control System Installation and User s Guide Notes...
Page 87: ......
Page 88: ...P N 520785 Rev A 520785...