32
IntelliFlo VS+ SVRS Installation and User’s Guide
Pump Strainer Basket Service
(Continued)
10. Ensure that the lid o-ring is properly placed. Seat the clamp and lid then
turn clockwise until the handles are horizontal as shown.
11. Reconnect the communication cable to the pump if required.
12. Switch the power ON at the circuit breaker. Reset the pool time clock
to the correct time.
WARNING —
FILTER OPERATES UNDER HIGH PRESSURE. WHEN
ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING,
PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER
THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED
AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT
IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS
POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
13. Open the manual air relief valve on top of the filter.
14. Stand clear of the filter. Press the Start button on the pump.
15. Bleed air from the filter until a steady stream of water comes out.
16. Close the manual air relief valve.
Motor Service
1.
Protect from heat:
•
Shade the motor and controller from the sun.
•
Any enclosure must be well ventilated to prevent overheating. Particular attention should be paid to the
motor fan cover and the cooling fins between the drive and the motor.
•
Provide ample cross ventilation.
2.
Protect against dirt:
•
Protect from any foreign matter or splashing water.
•
Do not store (or spill) pool chemicals near the motor.
•
Avoid sweeping or stirring up dust near the motor while it is operating.
•
If a motor has been damaged by dirt it voids the motor warranty.
3.
Protect against moisture:
•
Protect from splashing pool water.
•
Protect from the weather.
•
Protect from lawn sprinklers.
•
If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has been
flooded.
•
If a motor has been damaged by water it voids the motor warranty.
Note:
DO NOT wrap motor and controller with plastic or other air tight materials. The motor and
controller may be covered, but not wrapped in plastic, during a storm, for winter storage, etc., but
never when operating, or expecting operation.