20
IntelliFlo VS+ SVRS Installation and User’s Guide
Priming
(Continued)
4. Press the
Select
button. The factory default is set to priming “Enabled“.
5. To disable priming, press the
Select
button.
6. Use the
Up
arrow button. “Disabled” is displayed.
7. Press the
Enter
button.
8. Press the Down Arrow button. Screen will read "Max Priming Time". Factory default is set to 11
minutes.
9. Press the
Select
button to change the setting. The cursor will highlight the minutes column.
10. Use the Up or Down arrow button to change the time from 1 minute to 30 minutes..
11. Press the
Enter
button to save the setting.
12. Press the
Down arrow
button. The screen will read "Primed Sensitivity". The default for this setting
being "1".
13. Press the
Select
button to change the setting. The cursor will highlight the number.
14. Use the up or
Down arrow
button to change the time from 1% to 100%. Increasing the number
makes the Priming less sensitive.
15. Press
Enter
to save.
16. Press the
Down arrow
button. Screen will read "Priming Delay". The default for this setting is
20 seconds.
17. Press the
Select
button to change the Setting.
18. Use the
Up or Down arrow
button to change the setting from 1 second to 10 minutes. Caution:
Increasing the Priming Delay causes the pump to stay in the priming mode longer thus increasing the
amount of time the pump operates with the SVRS off.
19. Press the
Enter
button to save the setting.
Note:
To cancel a change, press the Escape button
instead of the
Enter
button to exit without saving.