iv
IntelliFlo 4 Installation and User’s Guide
General Installation Information
WARNING
— Pumps improperly sized or installed or used in applications other than for which
the pump was intended can result in severe personal injury or death. These risks
may include but not be limited to electric shock, fire, flooding, suction entrapment
or severe injury or property damage caused by a structural failure of the pump or
other system component.
WARNING
— The pump can produce high levels of suction within the suction side of the
plumbing system. These high levels of suction can pose a risk if a person comes
within the close proximity of the suction openings. A person can be seriously
injured by this high level of vacuum or may become trapped and drown. It is
absolutely critical that the suction plumbing be installed in accordance with the
latest national and local codes for swimming pools.
•
These instructions contain information for a variety of pump models and therefore some instructions
may not apply to a specific model. All models are intended for use in swimming pool applications. The
pump will function correctly only if it is properly sized to the specific application and properly installed.
IMPORTANT SAFETY PRECAUTIONS
(continued)
General Warnings
•
Never open the inside or the drive motor enclosure. There is a capacitor bank that holds a
230 VAC charge even when there is no power to the unit.
•
The IntelliFlo 4 pump is not submersible
•
The IntelliFlo 4 160 pump is capable of 174 GPM or 104 feet of head; use caution when
installing and programming to limit pumps performance potential with old or questionable
equipment
•
The IntelliFlo 4 100 pump is capable of 100 GPM or 85 feet of head; use caution when
installing and programming to limit pumps performance potential with old or questionable
equipment
•
Code requirements for the electrical connection differ from state to state. Install equipment in
accordance with the National Electrical Code and all applicable local codes and ordinances.
•
Always Press the Stop button and disconnect the communication cable before performing
maintenance