10
IntelliFlo 4 Installation and User’s Guide
Connecting IntelliFlo 4 to an EasyTouch System
The IntelliFlo 4 can be controlled by an IntelliTouch system via the RS-485 communication cable (PN
350122). In this configuration, IntelliTouch starts, stops and controls the speed of the IntelliFlo pump.
When the IntelliTouch does this, it rewrites the IntelliFlo 4 memory, which can take several seconds. This
causes a delay from when a command is given on the IntelliTouch control panel until the Intelliflo 4 physically
responds.
The IntelliFlo 4 control panel is disabled when communicating with the IntelliTouch system. Note that
IntelliTouch will not start communicating with the IntelliFlo 4 until the appropriate pump address is assigned
to a circuit. The IntelliFlo 4 default pump address is one. See page 6 for details on how to change the
address to 2, 3 or 4. For more information, refer to the IntelliTouch User's Guide (PN 520102).
To connect the IntelliFlo cable to EasyTouch load center:
1.
CAUTION
- Switch the main power off to the EasyTouch Load Center.
2. Unlatch the two enclosure door spring latches, and open the door.
3. Remove the two retaining screws securing the high voltage cover panel, and remove it from the
enclosure.
3. Loosen the two access screws securing the control panel.
EasyTouch Load Center (front view)
Control panel
access screw
Control panel
access screw
High voltage
cover panel
Retaining screw