background image

High Power Wireless Link Kit Installation Guide

 

6

 

                                                                                                                                                                                            

7

 

Connect the High Power Wireless (HPW) Indoor Transceiver to the ScreenLogic

®

 

Interface Protocol Adapter as follow: See Figure 6 on page 12.

1. 

Using the provided 1 ft. RS-485 cable, connect one end of the cable 
plug to the Protocol adapter and the other end to the HPW Link indoor 
transceiver. The cable plugs are keyed for easy connection. See diagram 
below. 

2. 

Plug the 120 VAC Power Adapter into an AC grounded electrical outlet. 
Plug the other end into the power socket on the HPW Link indoor 
transceiver. 

Wall Mount the HPW Indoor Transceiver (Figure 2 and Figure 3)

Mount the 

Mount the HPW Indoor Transceiver on an indoor wall as follows:

1. 

Cut out the wall mounting template from the next page. Place the template 
on an indoor flat surface or wall and mark the two screw hole positions. 

2. 

Drill two holes (0.223 in) 2-1/2 inches apart as shown on the template (see 
Figure 3 on next page).

3. 

Insert the wall plugs into both wall screw holes.

4. 

Insert the screws into the wall plug. Don’t insert the screws all the way into 
the wall, leave about 1/16 in for the wireless transceiver to hang on the 
head of the screws (see Figure 2 on next page).

5. 

Mount the wireless transceiver onto both screw heads.

Base/Desk Mount the HPW Indoor Transceiver (Figure 1 on page 7) 

Mount the HPW Indoor Transceiver in its base as follows:

1. 

Insert the power cable into the base of the HPW Link Indoor transceiver 
base. Fasten the cable into the cradle slot (see Figure 1 on page 7).

2. 

Insert the connection cable into the base of the transceiver cradle. Fasten 
the cable into the cradle slot (see Figure 1 on next page).

3. 

Place the transceiver and base on a table or desk. Note: Keep the 
transceiver clear of all objects for two feet.  Note: Do not place the 
transceiver on the floor or behind a desk.

Connecting the HPW Indoor Transceiver and Protocol Adapter

SCREENLOGIC   INTERFACE

®

Connection cable (1 ft) 
(provided in kit)

120 VAC 
Power Adapter

HPW Indoor 
Transceiver

Protocol 

Adapter

High Power Wireless Link For ScreenLogic 
Interface Systems 

Summary of Contents for HIGH POWER WIRELESS LINK KIT

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION GUIDE HIGH POWER WIRELESS LINK KIT FOR INTELLICENTER INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS...

Page 2: ...s 4 High Power Wireless Link Indoor Transceiver LEDs and Connectors 5 High Power Wireless Link For ScreenLogic Interface Systems 6 Mounting Indoor Transceiver 6 Mounting Outdoor Transceiver 8 Connect...

Page 3: ...accepter les interf rences qui peuvent causer un mauvais fonctionnement de l appareil Cet appareil num rique de classe B est conforme la norme canadienne ISDE RSP 100 section 2 1 et Terminal Equipment...

Page 4: ...ard wire connection from inside your home to the equipment pad Installation Guide This Installation Guide provides installation instructions for the High Power Wireless Link kit For information about...

Page 5: ...r and the ID number on the outdoor transceiver circuit board are the same RS 485 Connector to Protocol Adapter ScreenLogic only High Power Wireless Link Indoor Transceiver LEDs and Connectors High Pow...

Page 6: ...page 3 Insert the wall plugs into both wall screw holes 4 Insert the screws into the wall plug Don t insert the screws all the way into the wall leave about 1 16 in for the wireless transceiver to han...

Page 7: ...ting Screws Location Figure 2 Wall Mount the Indoor Wireless Transceiver Figure 1 Cradle Desk Mount the HPW Indoor Transceiver Hang module on screw head approx 1 16 in from wall surface 1 16 0 41 cm M...

Page 8: ...the back plate against the mounting surface so that the transceiver is oriented in an upright position with the antenna pointing upwards Use a pencil to mark the four mounting points Drill four 3 16...

Page 9: ...h Control System BLK RED YEL GRN BLK GND PIN 1 GRN DT PIN 2 YEL DT PIN 3 RED 15 V PIN 4 HPW Outdoor Transceiver circuit board Connect the HPW Link Outdoor Transceiver Cable to the RS 485 COM Port on A...

Page 10: ...ard sockets connectors for the electrical connections Remove the panel from the enclosure 5 Route the four conductor transceiver connection cable into the lower plastic grommet up through the low volt...

Page 11: ...M PORT terminal However this can cause an intermittent connection Note For additional COM ports an optional Serial COM Port Expansion Board P N 520818 can be installed in the low voltage compartment 7...

Page 12: ...home user RJ11 DSL or Cable Modem RJ11 for DSL Coax for Cable LAN PORTS Ethernet RJ45 CAT 5 to Wireless Router LAN Port AC Power Adapter Indoor wall outlet RJ45 SCREENLOGIC INTERFACE Figure 6 High Pow...

Page 13: ...See Figure 7 on page 14 5 Remove the two screws securing the existing transceiver and remove the transceiver from its mounting position 6 Connect the HPW Link Outdoor Transceiver Connect the Ethernet...

Page 14: ...Ethernet Port AUX 5 AUX 6 AUX 7 AUX 8 AUX 9 From Ethernet Port J14 IntelliCenter Control System main circuit board 2 Pin 24 VDC Socket to Power Module Power Cable Ethernet Cat5 Cable from HPW transce...

Page 15: ...wer opening of the Load Center or Power Center 6 Power Module Power Connection Connect the 24VDC connector into the Power Module DC IN socket and the plug other end into the IntelliCenter Control Syst...

Page 16: ...gistered trademark of Apple Corporation Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the ow...