6. 

Strip the leads of the communication cable wires back ¼ in. Insert 
the wires into the connector screw terminals. Using a small flat-
blade screwdriver, secure the wires with the COM PORT (J7/J8) 
terminal screws. Note: Multiple wires may be inserted into a single 

screw terminal. Be sure to match the color-coding of the wires: 

 

Pin 4 - Red = +15 VDC 
Pin 3 - Yellow = +DT 
Pin 2 - Green = -DT 

Pin 1 - Black = GND 

 

IntelliTouch

®

 (J7/J8) or 

EasyTouch

®

 Control 

System COM Ports 

(J20) screw terminal 

connector

Note: Multiple wires may be 
inserted into a single screw 
COM PORT terminal. However, 
this can cause an intermittent 
connection. Note: For additional 
COM ports, an optional Serial 
COM Port Expansion Board (P/N 
520818) can be installed in the 
low voltage compartment. 

7. 

After the communication cable connection has been completed; 
close the Outdoor Control Panel and tighten the two retaining 
screws. Reinstall the High Voltage Panel: Insert the panel’s three 
tabs into the lower slots on the enclosure. Secure the panel with the 
two (2) retaining screws. Close the front door and secure it with the 
latch.

8. 

Switch ON AC power to the Load Center.

9. 

After the Power Center is powered up the HPW Link outdoor 
transceiver will automatically synchronize with the system and will 
be ready for operation.  Note: The initial connection can take up 
to 2-3 minutes.

Summary of Contents for HIGH POWER WIRELESS LINK KIT

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION GUIDE HIGH POWER WIRELESS LINK KIT FOR INTELLICENTER INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS...

Page 2: ...s 4 High Power Wireless Link Indoor Transceiver LEDs and Connectors 5 High Power Wireless Link For ScreenLogic Interface Systems 6 Mounting Indoor Transceiver 6 Mounting Outdoor Transceiver 8 Connect...

Page 3: ...accepter les interf rences qui peuvent causer un mauvais fonctionnement de l appareil Cet appareil num rique de classe B est conforme la norme canadienne ISDE RSP 100 section 2 1 et Terminal Equipment...

Page 4: ...ard wire connection from inside your home to the equipment pad Installation Guide This Installation Guide provides installation instructions for the High Power Wireless Link kit For information about...

Page 5: ...r and the ID number on the outdoor transceiver circuit board are the same RS 485 Connector to Protocol Adapter ScreenLogic only High Power Wireless Link Indoor Transceiver LEDs and Connectors High Pow...

Page 6: ...page 3 Insert the wall plugs into both wall screw holes 4 Insert the screws into the wall plug Don t insert the screws all the way into the wall leave about 1 16 in for the wireless transceiver to han...

Page 7: ...ting Screws Location Figure 2 Wall Mount the Indoor Wireless Transceiver Figure 1 Cradle Desk Mount the HPW Indoor Transceiver Hang module on screw head approx 1 16 in from wall surface 1 16 0 41 cm M...

Page 8: ...the back plate against the mounting surface so that the transceiver is oriented in an upright position with the antenna pointing upwards Use a pencil to mark the four mounting points Drill four 3 16...

Page 9: ...h Control System BLK RED YEL GRN BLK GND PIN 1 GRN DT PIN 2 YEL DT PIN 3 RED 15 V PIN 4 HPW Outdoor Transceiver circuit board Connect the HPW Link Outdoor Transceiver Cable to the RS 485 COM Port on A...

Page 10: ...ard sockets connectors for the electrical connections Remove the panel from the enclosure 5 Route the four conductor transceiver connection cable into the lower plastic grommet up through the low volt...

Page 11: ...M PORT terminal However this can cause an intermittent connection Note For additional COM ports an optional Serial COM Port Expansion Board P N 520818 can be installed in the low voltage compartment 7...

Page 12: ...home user RJ11 DSL or Cable Modem RJ11 for DSL Coax for Cable LAN PORTS Ethernet RJ45 CAT 5 to Wireless Router LAN Port AC Power Adapter Indoor wall outlet RJ45 SCREENLOGIC INTERFACE Figure 6 High Pow...

Page 13: ...See Figure 7 on page 14 5 Remove the two screws securing the existing transceiver and remove the transceiver from its mounting position 6 Connect the HPW Link Outdoor Transceiver Connect the Ethernet...

Page 14: ...Ethernet Port AUX 5 AUX 6 AUX 7 AUX 8 AUX 9 From Ethernet Port J14 IntelliCenter Control System main circuit board 2 Pin 24 VDC Socket to Power Module Power Cable Ethernet Cat5 Cable from HPW transce...

Page 15: ...wer opening of the Load Center or Power Center 6 Power Module Power Connection Connect the 24VDC connector into the Power Module DC IN socket and the plug other end into the IntelliCenter Control Syst...

Page 16: ...gistered trademark of Apple Corporation Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the ow...

Reviews: