Installer Manual Fleck 4600 - MECH - Programming
Ref. MKT-IM-027 / B - 01.06.2018
51 / 88
6.4.2. Set the salt volume per regeneration
No.
Operation
A
Calculate the weight of salt needed per regeneration, see 6.4.1. Salt volume definition,
page 50.
B
Remove the screws (
2
) and the cover (
1
).
C
Loosen (
5
).
D
Adjust the segment of the brine cam (
4
) to the value calculated at point
A
on the sticker (
3
).
E
Tighten (
5
).
F
Replace the screws (
2
) and the cover (
1
).
Note
Example for the following drawing, the weight of salt set is 2 kg per regeneration.