4

MagicStream Laminar Installation and User’s Guide

Pentair recommends that the system pressure test be performed after the deck housing is mounted to the

supply piping.

5. Plug the flex line in the housing by disconnecting the union between the deck housing and the Laminar.
Using one of the Laminar adjustment nuts, secure the winterization cap to the supply side of the union.

 The pressure on the piping/plumbing supplying the Laminar should not exceed 50 PSI.

6. Once the deck is finished, flush any debris from the supply pipe using the pump and filter system that
supplies the Laminar.

 Any debris in the Laminar unit will hinder its ability to produce a turbulence-free stream.

Electrical Installation

1. Pull the 16 gauge, 3-conductor cable through the opening marked “electrical” in the deck housing  and
feed it via electrical conduit to the transformer’s location (Figure 2).  Leave 3 feet of slack at the deck
housing end to allow easy servicing.

2. Connect the LED wiring to the 12vac taps of the transformer.

3. Connect the 120vac side of the transformer to a 120vac GFCI power feed that is controlled by a single
switch.  When installing multiple laminars, make sure all the laminars are connected to a single switch.  You
will use this switching capability to program the LED light engine (See pages 10-11).

    WARNING 

— 

To avoid dangerous or fatal electrical shock hazard, all metal items within five (5) feet of the pool or

spa must be properly electrically bonded to a reliable grounding point. The Laminar canister must be properly electrically
bonded and grounded via the NO. 8 AWG ground connector located on the side of the canister.

Figure 2

Transformer
location

Filter

Pull 3-conductor cable
through the opening
marked “electrical” in the
deck housing and feed it
via electrical conduit to
the transformer’s
location.

Rebar

Ground wire

Summary of Contents for MagicStream Laminar

Page 1: ...MagicStream Laminar Installation and User s Guide IMPORTANTSAFETYINSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...

Page 2: ...ted companies in the United States and or other counties Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the pr...

Page 3: ...stallation and User s Guide Contents Important Safety Precautions ii Section 1 Overview 1 Section 2 Installation 3 Section 3 Setup and Operation 7 Section 4 Maintenance Troubleshooting 13 Section 5 Re...

Page 4: ...ancewiththeNationalElectricalCodeandallapplicable local codes and ordinances Improper installation will create an electrical hazard which could result in death or serious injury to pool users installe...

Page 5: ...s capable of generating a series of multi colored light shows or can be set to display a continuous singlecolor If desired thebuilt insolenoid thumper cancreatearandom wrinkle intheLaminar sstream cau...

Page 6: ...ater NOTE Proper drainage from the deck housing is critical to avoid damage to the Laminar Jet assembly Do not install the Laminar Jet deck housing in an area prone to run off or flooding Thedeckhousi...

Page 7: ...collar is at the level of the finished deck Figure1 Theadjustablecollarshouldbeangledsothatitwillalignflushwiththefinisheddeck surface Once you have made the final adjustments to the collar s angle g...

Page 8: ...lectrical conduit to the transformer s location Figure 2 Leave 3 feet of slack at the deck housingendtoalloweasyservicing 2 Connect the LED wiring to the 12vac taps of the transformer 3 Connect the 12...

Page 9: ...eknifeuntilitis cherry red NOTE Do not cut the fiber ends too close to the tape Leave a distance between the end of the cable and the tape This will prevent the adhesive on the tape from melting and a...

Page 10: ...6 MagicStream Laminar Installation and User s Guide Blank Page...

Page 11: ...duce a turbulence free stream Laminar Setup Make sure the supply piping has been flushed clear as directed above 1 Carefully spread the brackets and slide the Laminar unit into the holes in the bracke...

Page 12: ...ngLid 5 Placethedeckhousinglid Laminarunitinthedeckhousing Figure5 Ifthehosesinthedeckhousing prevent the proper seating of the deck housing lid you may have to loosen the union nut briefly and allow...

Page 13: ...a matter of taste We encourage you to experiment with the light enhancer to achieve the effectyoudesire NOTE Laminars are sensitive to wind earth movement and equipment vibration Secure the Laminar a...

Page 14: ...ndomly and slowly at first then speed up until the sequence ends with quick flashes and strobes The sequence then repeats beginning with the slow changes Inthismode multipleLaminarswillNOTchangecolors...

Page 15: ...uence In this mode multiple Laminars will NOT change colors together If the solenoid thumper mode is turned on the thumpers will thump at random intervals and multiple Laminars will NOT thump together...

Page 16: ...12 MagicStream Laminar Installation and User s Guide Blank Page...

Page 17: ...3 DisconnectthesupplyunionandturnontheLaminarsupplypumpuntilthewaterrunsclear 4 Reattach the union place the Laminar back in the deck housing and check the alignment of the stream 5 Replacethedeckhou...

Page 18: ...tofthewaterrunsout 6 Drainthefilterandblowoutthesupplyline 7 Usetheunionnutandplugtocapoffthesupplylinefromthefilter Figure6 8 Coil the deck housing supply hose and push it to the bottom of the housin...

Page 19: ...021 Laminar led light engine 2 590022 Laminar fiber optic adapter 3 590023 Laminar body no light 4 590024 Laminar housing no cover 5 590025 Laminar cover black 6 590026 Laminar cover gray 7 590027 Lam...

Page 20: ...P N 590033 Rev A...