2

MagicStream Laminar Installation and User’s Guide

Design Points

The Laminar arc can reach a maximum height of seven feet and a distance of eight feet.

To achieve the maximum Laminar arc height,  a water supply of 10gpm with 16 ft of head (measured at
the Laminar) is required.

Install the Laminar close to the edge of the pool to minimize water from splashing on the deck on windy
days.

Use a 20 micron cartridge filter to supply clean, filtered water to the Laminar.  Do not use a DE or Sand
filter.

Use 1" Sch40 PVC pipe to supply the Laminar.  On long pipe runs, calculate the pressure drop and
compensate by increasing the supply pressure.

Install a 1" ball or globe throttling valve on the water supply to EACH Laminar.  When installing more
than one Laminar, Pentair recommends installing a throttling valve on the main supply manifold.

Install a 1-1/2" drain line to the bottom of the Laminar deck housing and create a drain system to
prevent standing water.

NOTE:   Proper drainage from the deck housing is critical to avoid damage to the Laminar Jet
assembly.  Do not install the Laminar Jet deck housing in an area prone to run-off or flooding.

The deck housing electrical connection (marked "Electrical" on the housing) is designed for 1" PVC
conduit.  Create no more than 270º of turns in the conduit without an intermediate pull box.

If you opt for a fiber optic light source, choose one with 150-170 strands.  The Laminar will accept a
bundle of strands 1/2” in diameter.

The LED light engine comes with a 100' long 3-wire cable.  Use a 120/12VAC-100watt pool lighting
transformer (purchased separately) powered with a GFCI breaker.  Six Laminars can be powered
with one transformer.  Follow the National Electric Code and local codes to determine the placement of
the transformer.

Mount the deck housing so that the water supply and electrical connections are located opposite the
intended direction of the Laminar stream.  The Laminar’s orifice can rotate only 30 degrees to left or
right, so determine the intended direction of the Laminar stream and position the deck housing
accordingly.

Summary of Contents for MagicStream Laminar

Page 1: ...MagicStream Laminar Installation and User s Guide IMPORTANTSAFETYINSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...

Page 2: ...ted companies in the United States and or other counties Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the pr...

Page 3: ...stallation and User s Guide Contents Important Safety Precautions ii Section 1 Overview 1 Section 2 Installation 3 Section 3 Setup and Operation 7 Section 4 Maintenance Troubleshooting 13 Section 5 Re...

Page 4: ...ancewiththeNationalElectricalCodeandallapplicable local codes and ordinances Improper installation will create an electrical hazard which could result in death or serious injury to pool users installe...

Page 5: ...s capable of generating a series of multi colored light shows or can be set to display a continuous singlecolor If desired thebuilt insolenoid thumper cancreatearandom wrinkle intheLaminar sstream cau...

Page 6: ...ater NOTE Proper drainage from the deck housing is critical to avoid damage to the Laminar Jet assembly Do not install the Laminar Jet deck housing in an area prone to run off or flooding Thedeckhousi...

Page 7: ...collar is at the level of the finished deck Figure1 Theadjustablecollarshouldbeangledsothatitwillalignflushwiththefinisheddeck surface Once you have made the final adjustments to the collar s angle g...

Page 8: ...lectrical conduit to the transformer s location Figure 2 Leave 3 feet of slack at the deck housingendtoalloweasyservicing 2 Connect the LED wiring to the 12vac taps of the transformer 3 Connect the 12...

Page 9: ...eknifeuntilitis cherry red NOTE Do not cut the fiber ends too close to the tape Leave a distance between the end of the cable and the tape This will prevent the adhesive on the tape from melting and a...

Page 10: ...6 MagicStream Laminar Installation and User s Guide Blank Page...

Page 11: ...duce a turbulence free stream Laminar Setup Make sure the supply piping has been flushed clear as directed above 1 Carefully spread the brackets and slide the Laminar unit into the holes in the bracke...

Page 12: ...ngLid 5 Placethedeckhousinglid Laminarunitinthedeckhousing Figure5 Ifthehosesinthedeckhousing prevent the proper seating of the deck housing lid you may have to loosen the union nut briefly and allow...

Page 13: ...a matter of taste We encourage you to experiment with the light enhancer to achieve the effectyoudesire NOTE Laminars are sensitive to wind earth movement and equipment vibration Secure the Laminar a...

Page 14: ...ndomly and slowly at first then speed up until the sequence ends with quick flashes and strobes The sequence then repeats beginning with the slow changes Inthismode multipleLaminarswillNOTchangecolors...

Page 15: ...uence In this mode multiple Laminars will NOT change colors together If the solenoid thumper mode is turned on the thumpers will thump at random intervals and multiple Laminars will NOT thump together...

Page 16: ...12 MagicStream Laminar Installation and User s Guide Blank Page...

Page 17: ...3 DisconnectthesupplyunionandturnontheLaminarsupplypumpuntilthewaterrunsclear 4 Reattach the union place the Laminar back in the deck housing and check the alignment of the stream 5 Replacethedeckhou...

Page 18: ...tofthewaterrunsout 6 Drainthefilterandblowoutthesupplyline 7 Usetheunionnutandplugtocapoffthesupplylinefromthefilter Figure6 8 Coil the deck housing supply hose and push it to the bottom of the housin...

Page 19: ...021 Laminar led light engine 2 590022 Laminar fiber optic adapter 3 590023 Laminar body no light 4 590024 Laminar housing no cover 5 590025 Laminar cover black 6 590026 Laminar cover gray 7 590027 Lam...

Page 20: ...P N 590033 Rev A...