GENERAL INFORMATION
1
1. GENERAL INFORMATION
1.1 General warnings
– Installation
Read all safety warnings in the
“Instruction Manual”. The additional safety issues outlined below must also be
followed completely when installing this Boiler.
Use of a properly calibrated electronic combustion analyzer MUST be used when installing, servicing or
converting this Boiler from Natural Gas to LP or from LP to Natural Gas.
Failure to remove or maintain the area free of combustible material, gasoline and other flammable liquids or
vapors can result in severe personal injury, death or substantial property damage.
All applicable local, state, national and provincial codes, ordinances, regulations and laws must be observed.
For installations in Massachusetts
– code requires the units to be installed by a licensed plumbing or gas fitter.
If the hot water boiler is installed above radiation level or as required by the authority having jurisdiction, must be
provided with a low water cutoff device at the time of boiler installation.
Where required by the authority having jurisdiction, the installation must conform to the Standard for controls and
safety devices for automatically fired boilers, ANSI/ASME CSD1.
If an external electrical source is utilized, the appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with the National Electrical Codes ANSI/NFPA 70
and or the CSA C22.1 Canadian Electrical Code.
Follow all local codes and/or the most recent edition of the National Fuel Gas Code (ANSI Z223.1/NFPA
54) in the USA or the Natural Gas and Propane Installation Code in Canada (CAN/CSA B149.1).
This unit is designed for indoor installations. DO NOT operate this unit without the vent piping connected.
Exhaust gases must be completely expelled out of the building.
Do not use this appliance if any part has been underwater. Immediately call a qualified service
technician to inspect the appliance and replace any part of the control system and any gas control which
has been underwater.
Be sure not to reverse the water and gas connections as this may damage the gas valves.
Water temperatures over 125
°
F can cause severe burns instantly or death from scalding. If the proposed
boiler outlet temperature is above 125
°
F, a thermostatically controlled mixing valve (or a temperature
limiting valve) for reducing point of use water temperature is recommended to reduce the risk of scald
injury. Contact a licensed plumber or the local plumbing authority for further information.
The appliance should be located in an area where leakage within the unit or at its connections will not
result in damage to the area adjacent to the appliance or to lower floors of the structure. PENSOTTI will
not be responsible for any damage resulting from leaking if adequate drainage is not provided. When
such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be
installed under the appliance.
The flow of ventilation to the b oi l e r must not be obstructed. The b o i l e r area must be kept clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
If the water quality is known to be highly acidic and/or extremely hard, water treatments (ie water softeners and
filtration) are recommended to maintain full warranty. Consult the local water authority.
DO NOT over-tighten fittings, as pipe and/or fitting damage may occur causing leakage.
DO NOT install boiler where subject to vibrations.
For other than a direct vent appliance, the appliance must be located as close as possible to a chimney or gas
vent.
Should overheating occur or the gas supply fails to shut off, turn the manual gas control valve to the
appliance. Contact a Service Technician immediately.
Summary of Contents for PCC 34-H
Page 8: ...GENERAL INFORMATION 5 ...
Page 9: ...GENERALInformation 6 ING ...
Page 10: ...GENERALInformation 7 ...
Page 11: ...GENERALInformation 8 ...
Page 32: ...INSTALLATION INSTRUCTIONS 29 Venting Pictures Illustrations ...
Page 33: ...INSTALLATION INSTRUCTIONS 30 Included With Each Combination Boiler Is A PAHVK Horizontal Kit ...
Page 37: ...INSTALLATION INSTRUCTIONS 34 ...
Page 38: ...INSTALLATION INSTRUCTIONS 35 ...
Page 67: ...INSTALLATION INSTRUCTIONS 64 INDIRECT FIRED WATER HEATER 6 9 D H W sensor connection ...