Cyclone Universal & Cyclone Universal FX - User Manual
16
Figure 3-11: ColdFire Extension Cable With Adapter (P&E part# CABLE_CF_ADAPTER, for
synchronous ColdFire targets, sold separately)
Figure 3-12: ColdFire Ribbon Cable (for asynchronous ColdFire targets, included with Cyclone)
3.23
PORT E: 16-Pin Debug Connector (MON08)
The Cyclone provides a 16-pin 0.100-inch pitch double row connector for MON08 targets. The
location of the this header is indicated as PORT E in
Figure 3-5
. The MON08 header adopts the
standard pin-out from MON08 debugging with some modifications. The general pin-out is as
follows:
MON08 Signals
PIN 1 -
NC
GND
-
PIN 2
PIN 3 -
NC
RST
-
PIN 4
PIN 5 -
NC
IRQ
-
PIN 6
PIN 7 -
NC
MON4
-
PIN 8
PIN 9 -
NC
MON5
-
PIN10
PIN11 -
NC
MON6
-
PIN12
PIN13 -
OSC
MON7
-
PIN14
PIN15 -
Vout
MON8
-
PIN16
3.24
PORT F: 6-Pin Debug Connector (RS08, HCS08, HC(S)12(X), S12Z, Co/V1)
The Cyclone provides a standard 6-pin 0.100-inch pitch dual row 0.025-inch square header for
ColdFire V1, S12Z, 68(S)12(X), 68HCS08, and RS08 targets. The location of the this header is
indicated as PORT F in
Figure 3-5
. The header uses the NXP standard pin configuration, listed
here for reference:
ColdFire V1, 68(S)12(X), 68HCS08, and RS08 Signals
PIN 1 -
BKGD
GND -
PIN 2
PIN 3 -
NC
RESET -
PIN 4
PIN 5 -
NC
TVCC -
PIN 6
S12Z Signals
Note:
* indicates optional signal
PIN 1 -
BKGD
GND -
PIN 2
PIN 3 -
PDO*
RESET -
PIN 4
PIN 5 -
PDOCLK*
TVCC -
PIN 6