Operation

EASY-SMALL is switched off.

Press briefly 

or 

hold down

= nothing happens

Power is restored

 = EASY-SMALL 

resumes NORMAL SERVICE and starts  
the pump (if necessary).

No power supply

The system is pressurised. All taps are turned 
off. There is no demand for water. EASY-SMALL

 

detects an assembly pressure higher than that of 
the start-up pressure (Pm) and no flow.

Press briefly

 = the pump is started 

manually and runs for a few seconds 
before stopping again. 

Hold down

 = lthe pump is put OUT 

OF SERVICE. For instructions on how 
to reactivate the pump, see point 3.

A tap is turned on

 = as soon as the pressure 

falls below the start-up pressure (Pm), the pump 
is started.

NORMAL SERVICE: the pump is inactive.

The pump has been stopped manually. The pump 
will remain inactive until a new 
command is given.

Press briefly

= nothing happens.

Hold down

= the pump resumes NORMAL SERVICE. See 
points 2a - 2b.

OUT OF SERVICE

(See NOTE 1)
EASY-SMALL has detected that the pump is dry 
running and has therefore stopped it TEMPORA-
RILY.

Press briefly

 = the pump is started 

and manually and resumes NORMAL 
SERVICE.  See points 2a - 2b.

Hold down

= the pump is put OUT OF SERVICE. 
For instructions on how to reactivate the pump, 
see point 3. 

ERROR: stopped temporarily due to DRY RUNNING

The assembly requires water. One or more taps 
are turned on. EASY-SMALL detects a flow; the 
assembly pressure is normally higher than the 
START-UP pressure, but it may also be lower. 

Press briefly

 or 

hold down

= the pump is stopped and put OUT 
OF SERVICE. 
For instructions on how to reactivate 
the pump, see point 3.  

The taps are turned off

 = Sif there 

is no flow for a few seconds, the pump is stopped. 

NORMAL SERVICE: the pump is running

(see NOTE 2)
EASY-SMALL has detected that the pump 
starting-up too often and has therefore stopped it 
TEMPORARILY.

Press briefly

 = the pump is started 

and manually and resumes NORMAL 
SERVICE.  See points 2a - 2b.

Hold down

 = the pump will not 

restart and goes OUT OF ORDER. the 
pump is put OUT OF SERVICE. For instructions on 
how to reactivate the pump, see point 3.
 

ERROR: temporary shut down due to FREQUENT 
START UP

= Off

= On

= Flashing

= Flashing

Exploded view of spare parts

Attention

: when ordering spare 

parts, always state the position n° 
from the diagram below and the 
product code number found in the 
pressure-flow regulator technical 
data table.

1 - EASY-SMALL body
2 - Cover with EASY-SMALL board
3 - Valve unit
4 - Pressure gauge
5 - Cable gland

Article

Version

Size (mm)

Summary of Contents for 50066/315

Page 1: ...DATI DI TARGA corrispondano a quelli desiderati Condizioni operative A Fluidi ammessi non ammessi EASY SMALL utilizzabile con acqua pulita e liquidi non chi micamente aggressivi Se nel liquido sono pr...

Page 2: ...nde il led rosso Power immediatamente EASY SMALL rileva l assenza di pressione nell im pianto idraulico e fa partire la pompa si accende il led verde Status Se entro 15 secondi dall av viamento EASY S...

Page 3: ...di NOTA 1 EASY SMALL ha rilevato che la pompa sta mar ciando a secco quindi l ha fermata TEMPORA NEAMENTE BREVE pressione la pompa viene avviata e torna in FUNZIONAMENTO NORMALE Vedi punti 2a 2b LUNGA...

Page 4: ...ziale l impianto idraulico La valvola di EASY SMALL non si apre completamente Controllare che la valvola si muova liberamente e se necessario pulirla La pompa si ferma e riparte in continuazione Perdi...

Page 5: ...f the power lines can withstand the maximum current the cable bushings and circuit board cover have been properly assembled and secured see Electrical Connections Power supply network must be fitted w...

Page 6: ...p Priming the pump For instructions on how to prime fill the pump see the pump manual Attention EASY SMALL is fitted with a check valve do not use the EASY SMALL s outlet to fill the pump for priming...

Page 7: ...has detected that the pump is dry running and has therefore stopped it TEMPORA RILY Press briefly the pump is started and manually and resumes NORMAL SERVICE See points 2a 2b Hold down the pump is put...

Page 8: ...ck the water pipes EASY SMALL s valve will not open completely Check that the valve is not blocked by any foreign objects and clean if necessary The pump stops and starts repeatedly Leaks within the s...

Page 9: ...es y la tapa de la tarjeta est n ensamblados y apretados correctamente v ase el apartado Conexiones el ctricas la red de alimentaci n el ctrica est equipada con un dispositivo de protecci n adecuado f...

Page 10: ...dimiento de cebado llenado de la bomba consultar el manual de la bomba Atenci n EASY SMALL est dotado de una v lvula de retenci n no utilizar la boca de salida de EASY SMALL para tratar de llenar la b...

Page 11: ...FUERA DE SERVICIO v ase la NOTA 1 EASY SMALL detecta que la bomba est marchando en seco y por tanto la hacer parar TEMPORALMENTE BREVE presi n la bomba se enciende y vuelve al FUNCIONAMIENTO NORMAL V...

Page 12: ...tros o tuber a Controlar la instalaci n hidr ulica La v lvula de EASY SMALL no se abre completamente Controlar que la v lvula no est bloqueada por cuerpos extra os y si es necesario limpiarla La bomba...

Page 13: ...er l assemblage et le vis sage des chemins de c ble et du volet de la carte cf paragraphe Branchements lectriques le r seau d alimentation lec trique est quip de dispositifs de protection appropri s f...

Page 14: ...a notice du fabricant de la pompe m me Attention EASY SMALL est muni d un clapet anti retour ne pas utili ser l orifice de sortie de EASY SMALL pour essayer de remplir la pompe pour l amor age Aliment...

Page 15: ...a pompe est en train de marcher sec et l a donc arr t e MOMENTA NEMENT BREVE pression la pompe est mise en route et revient en FON CTIONNEMENT NORMAL Cf points 2a 2b LONGUE pression sans tre remise en...

Page 16: ...iltre ou de la tuyauterie V rifier l unit hydraulique Le clapet du EASY SMALL ne s ouvre pas compl tement V rifier si le clapet n est pas engorg par des corps trangers et le nettoyer en cas de besoin...

Page 17: ...kung korrekt zusammengebaut und angezogen sind siehe Absatz Elektroan schl sse Das elektrische Versor gungsnetz muss der EASY SMALL vorgelagert mit einem geeignetem Schutzme chanismus Schmelzsicherung...

Page 18: ...Pumpe verwiesen Achtung EASY SMALL ist mit einem R ckschlagventil ausgestattet Nicht den Austritt des EASY SMALL verwenden um die Pumpe zu f llen Spannung zuschalten Die rote LED leuchtet Power EASY...

Page 19: ...IEB siehe ANMERKUNG 1 EASY SMALL hat festgestellt dass die Pumpe TROCKEN l uft und sie VOR BERGEHEND angehalten KURZES Dr cken die Pumpe wird eingeschaltet und kehrt zum NORMALEN BETRIEB zur ck Siehe...

Page 20: ...on Filter oder Leitungen Die Hydraulik berpr fen Das Ventil des EASY SMALL ffnet nicht vollkommen Kontrollieren ob das Ventil frei beweglich ist und erforderlichenfalls reinigen St ndiges Anhalten und...

Page 21: ...0 30 15 50 m H 2 O ft H 2 O MANUALE ISTRUZIONI AR HU RU DE EN FR IT ES EASY SMALL Pm Qa EASY SMALL EASY SMALL 1 BSP 90 EASYLIN Dati tecnici 230 115 50 60 10 A 12 A 3 12 A 16 A 3 IP 65 Pm 0 8 1 5 2 2 Q...

Page 22: ...US START STOP POWER EASY SMALL EASY SMALL EASY SMALL EASY SMALL EASY SMALL EASY SMALL 1 BSP M 90 1 5 1 3 EASY SMALL Pm 0 3 0 5 Pm EASY SMALL EASY SMALL LIN PRESS POWER EASY SMALL STATUS 15 EASY SMALL...

Page 23: ...STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER F01113001 230 50 60 Hz 16 A 2 2 bar 2012 COD...

Page 24: ...4a Pm EASY SMALL START 4b EASY SMALL Qa Qa EASY SMALL STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER ST...

Page 25: ...y az adatt bla adatai megegyeznek a k v ntakkal zemeltet sifelt telek A Folyad kok AZ EASY SMALL tiszta v zzel illetve k miailag nem agressz v folyad kkal m k dtethet Ha a folyad k szennyez d seket ta...

Page 26: ...ellenes s get jelez sz razonfut s miatt Els be zemel s Az EASY SMALL be zemel se el tt a szivatty t annak haszn lati utas t s ban le rt m don fel kell t lteni v zzel Figyelem Az EASY SMALL egy be p te...

Page 27: ...a 2b pontokn l ZEMEN K V L L sd 1 megjegyz s Az EASY SMALL rz kelte hogy a szivatty sz razon fut s ideiglenesen le ll totta R viden nyomva a szivatty elindul s visszat r a norm l zemm dba L sd 2a 2b p...

Page 28: ...gy cs vezet k elt m d tt R szleges hidraulikus rendszer EASY SMALL szelepe nem nyit teljesen Ellen rizz k hogy a szelep szabadon mozog e ha sz ks ges tiszt tsuk ki A szivatty ki be kapcsol Sziv rg s a...

Page 29: ...TOP STATUS Pm Pm POWER START STOP STATUS POWER START STOP STATUS 3 POWER START STOP STATUS START 4 Pm POWER START STOP STATUS START 4 POWER START STOP STATUS POWER START STOP STATUS POWER START STOP S...

Page 30: ...3 Pm 3 Pm 2 1 5 4 3 1 2 3 4 5 POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS PO...

Page 31: ...TOR GROUND U N V L GROUND LINE LINE POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS Power Status 15 START STOP Pm 1 1 5 Pm IP65 Pm 1 15 60 30 15 1 BSP 90 1 3 1 5 2 0 5 gpm 2 0...

Page 32: ...60 1 HP 3 12A 10A 2 HP 3 16A 12A IP 65 2 2 1 5 0 8 Pm 12 22 32 psi Qa 0 5 GPM 2 1 M BSP 1 F BSP 2 150 psi 10 580 psi 40 105 F 40 C 120 F 50 C 550 1C 1000 100000 3A 2 2 5 kV EMC 12 230 10 CODE V I max...

Reviews: