ELECTRONIC PUMP CONTROLLER

USER’S MANUAL

Technical specifications

Operating conditions

A. Compatible/non compa-
tible fluids 

EASY-SMALL is suitable for use 
with clean water and chemical-
ly non-aggressive liquids. If the 
fluid contains impurities, a filter 
should be fitted upstream.

B. Environmental conditions

EASY-SMALL should not be 
used where there is the risk of 
an explosion. The temperature 
of the location should range 
between 0°C and 40°C, and 
the humidity should not exceed 
90%.

C. Power supply

Make sure that the variation 

in the power supply is never 
more or less than 10 % of the 
RATING value. 
Higher values may cause 

damage to the electronic 
components.
EASY-SMALL can only be used 
with single-phase pumps.

Working area

Flow rate

Pressure

Shut-off flow rate

Start-up pressure

2

  l/min 

(0,5 gpm)

Qa

Pm

Safety regulations 

Before installing or using 
EASY-SMALL, read this manual 
carefully and thoroughly.
The pump should be installed 
and serviced by qualified per-
sonnel, responsible for making 
the hydraulic and electrical 
connections in compliance with 
the relevant regulations.
PEDROLLO shall not be 
held liable for any damage 
relating to, or resulting from, an 
improper use of the product, 
or for any damage relating to, 
or resulting from, servicing or 
repairs carried out by unqua-
lified personnel and/or with 
non-OEM spare parts. 
The warranty, which is valid 
for 24 months from the date 
of purchase, will no longer be 
applicable should the product 
suffer damage as a conse-
quence of the use of non-OEM 
spare parts, tampering or 
improper use. 
When starting the installation, 
check the following:

- the power supply is switched 
off.
- the power lines can withstand 
the maximum current.
- the cable bushings and circuit 
board cover have been properly 
assembled and secured ( see 
Electrical Connections ).
- Power supply network must 
be fitted with proper protection 
device (fuse or magneto-
thermal relay) upstream of 
EASY-SMALL
When servicing the product, 
check the following:
- the system is not pressurised 
(turn a tap on)
- the power supply is switched 
off.

Emergency Stop

When in use, the pump can 
be stopped in the event of an 
emergency: 
press START/STOP.  

EASY-SMALL is put OUT OF 
SERVICE.

EASY-SMALL is a device that 
starts and stops the pump to 
which it is fitted, thus replacing 
traditional pressure switch / 
surge tank systems. The pump 
is started when, as a tap is 
turned on, the pressure within 
the system drops below the 
“start-up pressure” (Pm), and 
is stopped when the flow rate 
required is zero or less than the 

“shut-off flow rate” (Qa). EASY-
SMALL’s electronics protect 
the pump against unsuitable 
operating conditions such as 
dry running or repeated start-
ups due to leaks.
EASY-SMALL features two 
threaded  1” BSP female 
outlets, positioned at 90° the 
one to the other, to be able to 
directly fit an expansion tank 

to the device; this is useful in 
case of any system drips, to 
prevent the continual restart of 
EASY-SMALL. 

Losses

- Voltage: ~230 Volt  / ~115 Volt.
- Frequency: 50-60 Hz
- Current: 10A, max 12A for 3 seconds
- Current: 12A, max 16A for 3 seconds
-  Protection grade: IP 65
- Operating pressure (Pm): 
  0.8 / 1.5 / 2.2 bar (12 / 22 / 32 psi)
- Stop capacity (Qa): 2 l/min (0.5 GPM)
- Suction connection: 1” M BSP
- Supply connections (2): 1” F BSP
- Max operating pressure: 
  10 bar (150 psi)
-  Burst pressure: 40 bar (580 psi)
-  Max ambient temperature:
  + 40 °C ( + 105 °F)
- Max liquid temperature withstandable 
  by materials: 50°C ( + 120 °F) 
-  Weight: 550 g
-  Protection against: 
  - dry running ( automatic restart) 
  - repeated start-ups
- Type of drive: 1C
- Max manual operations on 
  push button: 1000
- Max automatic operations on 
 relay: 100000
- Class 3A PTI
- Pollution degree : 2
- Max rated voltage pulse: 2,5 kV
- 230V 12A for EMC test
- Pressure operating 
  differential: 10 bar

Before installing, 

the product, check that 
the RATINGS correspond 
with those required.

Summary of Contents for 50066/315

Page 1: ...DATI DI TARGA corrispondano a quelli desiderati Condizioni operative A Fluidi ammessi non ammessi EASY SMALL utilizzabile con acqua pulita e liquidi non chi micamente aggressivi Se nel liquido sono pr...

Page 2: ...nde il led rosso Power immediatamente EASY SMALL rileva l assenza di pressione nell im pianto idraulico e fa partire la pompa si accende il led verde Status Se entro 15 secondi dall av viamento EASY S...

Page 3: ...di NOTA 1 EASY SMALL ha rilevato che la pompa sta mar ciando a secco quindi l ha fermata TEMPORA NEAMENTE BREVE pressione la pompa viene avviata e torna in FUNZIONAMENTO NORMALE Vedi punti 2a 2b LUNGA...

Page 4: ...ziale l impianto idraulico La valvola di EASY SMALL non si apre completamente Controllare che la valvola si muova liberamente e se necessario pulirla La pompa si ferma e riparte in continuazione Perdi...

Page 5: ...f the power lines can withstand the maximum current the cable bushings and circuit board cover have been properly assembled and secured see Electrical Connections Power supply network must be fitted w...

Page 6: ...p Priming the pump For instructions on how to prime fill the pump see the pump manual Attention EASY SMALL is fitted with a check valve do not use the EASY SMALL s outlet to fill the pump for priming...

Page 7: ...has detected that the pump is dry running and has therefore stopped it TEMPORA RILY Press briefly the pump is started and manually and resumes NORMAL SERVICE See points 2a 2b Hold down the pump is put...

Page 8: ...ck the water pipes EASY SMALL s valve will not open completely Check that the valve is not blocked by any foreign objects and clean if necessary The pump stops and starts repeatedly Leaks within the s...

Page 9: ...es y la tapa de la tarjeta est n ensamblados y apretados correctamente v ase el apartado Conexiones el ctricas la red de alimentaci n el ctrica est equipada con un dispositivo de protecci n adecuado f...

Page 10: ...dimiento de cebado llenado de la bomba consultar el manual de la bomba Atenci n EASY SMALL est dotado de una v lvula de retenci n no utilizar la boca de salida de EASY SMALL para tratar de llenar la b...

Page 11: ...FUERA DE SERVICIO v ase la NOTA 1 EASY SMALL detecta que la bomba est marchando en seco y por tanto la hacer parar TEMPORALMENTE BREVE presi n la bomba se enciende y vuelve al FUNCIONAMIENTO NORMAL V...

Page 12: ...tros o tuber a Controlar la instalaci n hidr ulica La v lvula de EASY SMALL no se abre completamente Controlar que la v lvula no est bloqueada por cuerpos extra os y si es necesario limpiarla La bomba...

Page 13: ...er l assemblage et le vis sage des chemins de c ble et du volet de la carte cf paragraphe Branchements lectriques le r seau d alimentation lec trique est quip de dispositifs de protection appropri s f...

Page 14: ...a notice du fabricant de la pompe m me Attention EASY SMALL est muni d un clapet anti retour ne pas utili ser l orifice de sortie de EASY SMALL pour essayer de remplir la pompe pour l amor age Aliment...

Page 15: ...a pompe est en train de marcher sec et l a donc arr t e MOMENTA NEMENT BREVE pression la pompe est mise en route et revient en FON CTIONNEMENT NORMAL Cf points 2a 2b LONGUE pression sans tre remise en...

Page 16: ...iltre ou de la tuyauterie V rifier l unit hydraulique Le clapet du EASY SMALL ne s ouvre pas compl tement V rifier si le clapet n est pas engorg par des corps trangers et le nettoyer en cas de besoin...

Page 17: ...kung korrekt zusammengebaut und angezogen sind siehe Absatz Elektroan schl sse Das elektrische Versor gungsnetz muss der EASY SMALL vorgelagert mit einem geeignetem Schutzme chanismus Schmelzsicherung...

Page 18: ...Pumpe verwiesen Achtung EASY SMALL ist mit einem R ckschlagventil ausgestattet Nicht den Austritt des EASY SMALL verwenden um die Pumpe zu f llen Spannung zuschalten Die rote LED leuchtet Power EASY...

Page 19: ...IEB siehe ANMERKUNG 1 EASY SMALL hat festgestellt dass die Pumpe TROCKEN l uft und sie VOR BERGEHEND angehalten KURZES Dr cken die Pumpe wird eingeschaltet und kehrt zum NORMALEN BETRIEB zur ck Siehe...

Page 20: ...on Filter oder Leitungen Die Hydraulik berpr fen Das Ventil des EASY SMALL ffnet nicht vollkommen Kontrollieren ob das Ventil frei beweglich ist und erforderlichenfalls reinigen St ndiges Anhalten und...

Page 21: ...0 30 15 50 m H 2 O ft H 2 O MANUALE ISTRUZIONI AR HU RU DE EN FR IT ES EASY SMALL Pm Qa EASY SMALL EASY SMALL 1 BSP 90 EASYLIN Dati tecnici 230 115 50 60 10 A 12 A 3 12 A 16 A 3 IP 65 Pm 0 8 1 5 2 2 Q...

Page 22: ...US START STOP POWER EASY SMALL EASY SMALL EASY SMALL EASY SMALL EASY SMALL EASY SMALL 1 BSP M 90 1 5 1 3 EASY SMALL Pm 0 3 0 5 Pm EASY SMALL EASY SMALL LIN PRESS POWER EASY SMALL STATUS 15 EASY SMALL...

Page 23: ...STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER F01113001 230 50 60 Hz 16 A 2 2 bar 2012 COD...

Page 24: ...4a Pm EASY SMALL START 4b EASY SMALL Qa Qa EASY SMALL STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER STATUS START STOP POWER ST...

Page 25: ...y az adatt bla adatai megegyeznek a k v ntakkal zemeltet sifelt telek A Folyad kok AZ EASY SMALL tiszta v zzel illetve k miailag nem agressz v folyad kkal m k dtethet Ha a folyad k szennyez d seket ta...

Page 26: ...ellenes s get jelez sz razonfut s miatt Els be zemel s Az EASY SMALL be zemel se el tt a szivatty t annak haszn lati utas t s ban le rt m don fel kell t lteni v zzel Figyelem Az EASY SMALL egy be p te...

Page 27: ...a 2b pontokn l ZEMEN K V L L sd 1 megjegyz s Az EASY SMALL rz kelte hogy a szivatty sz razon fut s ideiglenesen le ll totta R viden nyomva a szivatty elindul s visszat r a norm l zemm dba L sd 2a 2b p...

Page 28: ...gy cs vezet k elt m d tt R szleges hidraulikus rendszer EASY SMALL szelepe nem nyit teljesen Ellen rizz k hogy a szelep szabadon mozog e ha sz ks ges tiszt tsuk ki A szivatty ki be kapcsol Sziv rg s a...

Page 29: ...TOP STATUS Pm Pm POWER START STOP STATUS POWER START STOP STATUS 3 POWER START STOP STATUS START 4 Pm POWER START STOP STATUS START 4 POWER START STOP STATUS POWER START STOP STATUS POWER START STOP S...

Page 30: ...3 Pm 3 Pm 2 1 5 4 3 1 2 3 4 5 POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS PO...

Page 31: ...TOR GROUND U N V L GROUND LINE LINE POWER START STOP STATUS POWER START STOP STATUS POWER START STOP STATUS Power Status 15 START STOP Pm 1 1 5 Pm IP65 Pm 1 15 60 30 15 1 BSP 90 1 3 1 5 2 0 5 gpm 2 0...

Page 32: ...60 1 HP 3 12A 10A 2 HP 3 16A 12A IP 65 2 2 1 5 0 8 Pm 12 22 32 psi Qa 0 5 GPM 2 1 M BSP 1 F BSP 2 150 psi 10 580 psi 40 105 F 40 C 120 F 50 C 550 1C 1000 100000 3A 2 2 5 kV EMC 12 230 10 CODE V I max...

Reviews: