background image

5

LOW (12)

An active tone control (shelving type, 

±

15 dB) that varies the low frequency boost or cut.

GRAPHIC SELECT (13)

The "in" position of this switch routes the signal through the graphic equalizer. The "out" position removes the
graphic equalizer from the signal path.

7-BAND GRAPHIC EQ (14)

A 7-band, two-and-one-half-octave graphic equalizer that provides 15 dB of boost or cut at each center frequency.

CROSSOVER BALANCE CONTROL (15)

Controls the relative levels of output signals from the crossover. Adjusting this control will only affect signals at
the High Range Output Jack and the Low Range Output Jack on the rear panel. All other output signals are
unaffected by this control.

MASTER VOLUME (16)

Controls the overall volume level of the system.

CROSSOVER FREQUENCY (17)

The frequency control varies the crossover frequency from 100 Hz to 1 kHz.

POWER LED/DDT™ INDICATOR (18)

The LED is green when the power switch is in the "on" position. During normal operation, this LED also acts as a
DDT™ indicator. The LED illuminates "red" when DDT™ power amp compression is taking place.

POWER SWITCH (19)

Used to turn AC mains power on or off.

CIRCUIT BREAKER (20)

This breaker is provided to limit the current to the power transformer, and thereby protect it from overheating and
possible destruction due to faulty conditions in the amplifier. The trip current value has been carefully chosen to
allow continuous power output performance, while still providing adequate protection for the power transformer.
Normally this breaker should not trip unless there is a fault in the amplifier circuitry that draws excessive mains
current. However, abnormal conditions, such as a short circuit or continuous operation at overload or clipping,
will cause the breaker to trip. If this occurs, simply reset the breaker and correct the cause of the overload. When
tripped, the button on the breaker will be outward nearly 1/2" and can be reset by pushing inward. A normal reset
button length is about 1/4". If this “thermal” type breaker does trip, then simply pushing the button back in will
reset it after waiting a brief period of time to allow it to cool down. If the breaker trips instantly each time you
attempt to reset it, then the unit should be taken to a qualified service center for repair.

33

32

31

30

29

28

27

25

26

24

23

22

20

21

Summary of Contents for TMax

Page 1: ...1 Cover for T MAX ...

Page 2: ...ymbole est utilisé pur indiquer à l utilisateur la présence à l intérieur de ce produit de tension non isolée dangereuse pouvant être d intensité suffisante pour constituer un risque de choc électrique Ce symbole est utilisé pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions sur l utilisation et l entretien service de l appareil dans la littérature accompagnant le p...

Page 3: ...tortion sound that can t be found in any modern solid state bass rig FEATURES 1 4 input with 10 dB pad switch Active low and high shelving EQ with 7 band graphic EQ Front panel channel select and channel combine switches Channel active LEDs Variable 100 Hz 1 kHz third octave crossover with frequency and balance controls Front panel graphic in out switch Footswitchable channel select graphic in out...

Page 4: ...TOR 8 This LED indicates when lit that the input gain stage is being overdriven distorted Depressing the input pad switch to its in position or reducing the pre gain will alleviate this problem CHANNEL SELECT SWITCH 9 Allows selection of the tube or solid state channel The in position of the switch selects the solid state channel and the out position selects the tube channel NOTE Channel selection...

Page 5: ... is taking place POWER SWITCH 19 Used to turn AC mains power on or off CIRCUIT BREAKER 20 This breaker is provided to limit the current to the power transformer and thereby protect it from overheating and possible destruction due to faulty conditions in the amplifier The trip current value has been carefully chosen to allow continuous power output performance while still providing adequate protect...

Page 6: ... made from the line out jack or lifted to eliminate ground loop from unit and external source There may be some situations when audible hum and or noise will come from the loudspeaker Select the ground switch to either the in or out position to minimize the noise POWER AMP INPUT 27 Used to connect line level signal to the power amplifier PREAMP OUT 28 The preamp output can be used to route the amp...

Page 7: ...nel 10 dB Pad In Nominal Input 0 422 V RMS 7 5 dB Minimum Input 50 mV RMS 26 dB Maximum Input 6 0 V RMS 15 5 dB Tube Channel 10 dB Pad Out Post Gain 5 Nominal Input 0 054 V RMS 25 3 dB Minimum Input 5 mV RMS 46 dB Post Gain 10 Maximum Input 1 0 V RMS 0 dB For Clean Signal Tube Channel 10 dB Pad In Nominal Input 0 160 V RMS 16 dB Minimum Input 15 mV RMS 36 5 dB Post Gain 10 Maximum Input 3 V RMS 9 ...

Page 8: ...ight then use Master Volume for playing level ROCK FUNK COUNTRY NOTE Above settings for use with Solid State or Tube Channel NOTES FOR TUBE CHANNEL Distortion Set Pre Gain very high usually above 5 Keep Post Gain set low Clean Set Post Gain 10 and set Pre Gain low below 5 ...

Page 9: ... pulg puede reposicionarse al oprimirse otra vez La longitud normal de un botón reposicionado es aproximadamente 6 mm 1 4 pulg Si este cortacircuito tipo térmico en efecto se dispara simplemente habrá que aguardar un breve período de tiempo para que se enfríe y luego podrá reposicionarse al oprimir nuevamente el botón Si el cortacircuito se dispara instantáneamente cada vez que usted trata de repo...

Page 10: ...ncia y el control de equilibrio de entrecruzamiento ENTRECRUZAMIENTO SALIDA ALTA 30 Proporciona una señal de salida de alto rango después del entrecruzamiento El nivel de la señal se ajusta mediante el control de postganancia y el control de equilibrio de entrecruzamiento CONMUTADOR DE NIVEL DE EFECTOS EFX LEVEL 33 Selecciona el nivel de funcionamiento del circuito de efectos 10 dBV 3 V RMS cuando...

Page 11: ...11 ...

Page 12: ...eur normale du bouton est de 6 3 mm 1 2 po Si ce type de coupe circuit thermique disjoncte le réarmer en enfonçant le bouton dans sa position normale après avoir patienté quelques instants pour le laisser refroidir Si le disjoncteur se déclenche instantanément à chaque tentative de réarmement apporter l appareil à un centre de réparations qualifié FICHES DE HAUT PARLEURS 22 Ces prises permettent l...

Page 13: ...EUR CROSSOVER SORTIE HAUTES FRÉQUENCES 30 Il fournit le signal de sortie hautes fréquences post crossover Le niveau du signal est ajusté par les potentiomètres de gain post et de balance de crossover COMMUTATEUR DE NIVEAU D EFFETS 33 Ce commutateur sélectionne le niveau de fonctionnement de la boucle d effets 10dBV 3 V RMS en position basse et 0 dBV 1V RMS en position haute 33 32 31 30 29 28 27 25...

Page 14: ...14 ...

Page 15: ...ur etwa 0 6 cm heraus Wenn dieser Thermoschalter ausgelöst wird kann er nach kurzem Abkühlen des Geräts durch einfaches Eindrücken wieder zurückgesetzt werden Wenn der Unterbrecher sofort wieder auslöst sollte das Gerät von einem Fachmann überprüft werden LAUTSPRECHERBUCHSEN 22 An diese Buchsen können externe Lautsprecher oder Boxen angeschlossen werden Die minimale Gesamtimpedanz beträgt 2 Ohm DI...

Page 16: ...OVER HOCHFREQUENZ AUSGANG 30 An diesem Ausgang liegt ein Post Crossover Ausgangssignal im Hochtonbereich an Der Signalpegel wird durch die Post Gain Steuerung nach Verstärkung und die Crossover Balance Regelung ausgesteuert EFX PEGEL SCHALTER 33 Über diesen Schalter wird der Betriebspegel der Effektschleife ausgewählt 10 dBV 3 V RMS in Ein Position low und 0 dBV 1 V RMS wenn in Aus Position high 3...

Page 17: ...17 ...

Page 18: ...priate Peavey catalog publication Bass Guitars Guitars Bass Amplification Guitar Amplification Sound Reinforcement Enclosures Microphones Keyboards DJ Lighting Mixers Powered Non Powered Accessories Cables Effects Processors Axcess Wear The Peavey Beat Monitor Magazine Key Issues Low Down PM Magazine ...

Page 19: ...arranties and the other terms and conditions expressed herein have been complied with Peavey will provide the necessary warranty service to repair or replace the product and will return it FREIGHT COLLECT to you the purchaser Peavey s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action including negligence is limited to the actual damages up to the...

Page 20: ...en so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings 15 This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit does not operate correctly d The unit has been dropped or the enclosure damaged 16 The user sho...

Reviews: