background image

20

IMPORTANT SAFETY INSTRUCTIONS

WARNING: When using electric products, basic cautions should always be followed, including the following.

1.

Read all safety and operating instructions before using this product.

2.

All safety and operating instructions should be retained for future reference.

3.

Obey all cautions in the operating instructions and on the back of the unit.

4.

All operating instructions should be followed.

5.

This product should not be used near water, i.e., a bathtub, sink, swimming pool, wet basement, etc.

6.

This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a
wall or placed in a built-in enclosure that will impede the flow of cooling air.

7.

This product should not be placed near a source of heat such as a stove, radiator, or another heat producing amplifier.

8.

Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.

9.

Never break off the ground pin on the power supply cord. For more information on grounding, write for our free booklet “Shock
Hazard and Grounding.”

10.

Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords. Periodically check
cords for cuts or signs of stress, especially at the plug and the point where the cord exits the unit.

11.

The power supply cord should be unplugged when the unit is to be unused for long periods of time.

12.

If this product is to be mounted in an equipment rack, rear support should be provided.

13.

Metal parts can be cleaned with a damp rag. The vinyl covering used on some units can be cleaned with a damp rag or an ammonia-
based household cleaner if necessary. Disconnect unit from power supply before cleaning.

14.

Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other
openings.

15.

This unit should be checked by a qualified service technician if:
a.

The power supply cord or plug has been damaged.

b.

Anything has fallen or been spilled into the unit.

c.

The unit does not operate correctly.

d.

The unit has been dropped or the enclosure damaged.

16.

The user should not attempt to service this equipment. All service work should be done by a qualified service technician.

17.

This product should be used only with a cart or stand that is recommended by Peavey Electronics.

18.

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise
induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time.
The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level
exposures.

Duration Per Day In Hours

Sound Level dBA, Slow Response

8

90

6

92

4

95

3

97

2

100

1 1/2

102

1

105

1/2

110

1/4 or less

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss.
Ear plugs or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a
permanent hearing loss if exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high
sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as
this amplification system be protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

Features and specifications subject to change without notice.

Peavey Electronics Corporation 711 A Street / Meridian, MS 39301 / U.S.A. / (601) 483-5365 / Fax 486-1278

©1995                                                                              #80302264                                                            Printed in U.S.A. 4/95

®

Summary of Contents for TMax

Page 1: ...1 Cover for T MAX ...

Page 2: ...ymbole est utilisé pur indiquer à l utilisateur la présence à l intérieur de ce produit de tension non isolée dangereuse pouvant être d intensité suffisante pour constituer un risque de choc électrique Ce symbole est utilisé pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions sur l utilisation et l entretien service de l appareil dans la littérature accompagnant le p...

Page 3: ...tortion sound that can t be found in any modern solid state bass rig FEATURES 1 4 input with 10 dB pad switch Active low and high shelving EQ with 7 band graphic EQ Front panel channel select and channel combine switches Channel active LEDs Variable 100 Hz 1 kHz third octave crossover with frequency and balance controls Front panel graphic in out switch Footswitchable channel select graphic in out...

Page 4: ...TOR 8 This LED indicates when lit that the input gain stage is being overdriven distorted Depressing the input pad switch to its in position or reducing the pre gain will alleviate this problem CHANNEL SELECT SWITCH 9 Allows selection of the tube or solid state channel The in position of the switch selects the solid state channel and the out position selects the tube channel NOTE Channel selection...

Page 5: ... is taking place POWER SWITCH 19 Used to turn AC mains power on or off CIRCUIT BREAKER 20 This breaker is provided to limit the current to the power transformer and thereby protect it from overheating and possible destruction due to faulty conditions in the amplifier The trip current value has been carefully chosen to allow continuous power output performance while still providing adequate protect...

Page 6: ... made from the line out jack or lifted to eliminate ground loop from unit and external source There may be some situations when audible hum and or noise will come from the loudspeaker Select the ground switch to either the in or out position to minimize the noise POWER AMP INPUT 27 Used to connect line level signal to the power amplifier PREAMP OUT 28 The preamp output can be used to route the amp...

Page 7: ...nel 10 dB Pad In Nominal Input 0 422 V RMS 7 5 dB Minimum Input 50 mV RMS 26 dB Maximum Input 6 0 V RMS 15 5 dB Tube Channel 10 dB Pad Out Post Gain 5 Nominal Input 0 054 V RMS 25 3 dB Minimum Input 5 mV RMS 46 dB Post Gain 10 Maximum Input 1 0 V RMS 0 dB For Clean Signal Tube Channel 10 dB Pad In Nominal Input 0 160 V RMS 16 dB Minimum Input 15 mV RMS 36 5 dB Post Gain 10 Maximum Input 3 V RMS 9 ...

Page 8: ...ight then use Master Volume for playing level ROCK FUNK COUNTRY NOTE Above settings for use with Solid State or Tube Channel NOTES FOR TUBE CHANNEL Distortion Set Pre Gain very high usually above 5 Keep Post Gain set low Clean Set Post Gain 10 and set Pre Gain low below 5 ...

Page 9: ... pulg puede reposicionarse al oprimirse otra vez La longitud normal de un botón reposicionado es aproximadamente 6 mm 1 4 pulg Si este cortacircuito tipo térmico en efecto se dispara simplemente habrá que aguardar un breve período de tiempo para que se enfríe y luego podrá reposicionarse al oprimir nuevamente el botón Si el cortacircuito se dispara instantáneamente cada vez que usted trata de repo...

Page 10: ...ncia y el control de equilibrio de entrecruzamiento ENTRECRUZAMIENTO SALIDA ALTA 30 Proporciona una señal de salida de alto rango después del entrecruzamiento El nivel de la señal se ajusta mediante el control de postganancia y el control de equilibrio de entrecruzamiento CONMUTADOR DE NIVEL DE EFECTOS EFX LEVEL 33 Selecciona el nivel de funcionamiento del circuito de efectos 10 dBV 3 V RMS cuando...

Page 11: ...11 ...

Page 12: ...eur normale du bouton est de 6 3 mm 1 2 po Si ce type de coupe circuit thermique disjoncte le réarmer en enfonçant le bouton dans sa position normale après avoir patienté quelques instants pour le laisser refroidir Si le disjoncteur se déclenche instantanément à chaque tentative de réarmement apporter l appareil à un centre de réparations qualifié FICHES DE HAUT PARLEURS 22 Ces prises permettent l...

Page 13: ...EUR CROSSOVER SORTIE HAUTES FRÉQUENCES 30 Il fournit le signal de sortie hautes fréquences post crossover Le niveau du signal est ajusté par les potentiomètres de gain post et de balance de crossover COMMUTATEUR DE NIVEAU D EFFETS 33 Ce commutateur sélectionne le niveau de fonctionnement de la boucle d effets 10dBV 3 V RMS en position basse et 0 dBV 1V RMS en position haute 33 32 31 30 29 28 27 25...

Page 14: ...14 ...

Page 15: ...ur etwa 0 6 cm heraus Wenn dieser Thermoschalter ausgelöst wird kann er nach kurzem Abkühlen des Geräts durch einfaches Eindrücken wieder zurückgesetzt werden Wenn der Unterbrecher sofort wieder auslöst sollte das Gerät von einem Fachmann überprüft werden LAUTSPRECHERBUCHSEN 22 An diese Buchsen können externe Lautsprecher oder Boxen angeschlossen werden Die minimale Gesamtimpedanz beträgt 2 Ohm DI...

Page 16: ...OVER HOCHFREQUENZ AUSGANG 30 An diesem Ausgang liegt ein Post Crossover Ausgangssignal im Hochtonbereich an Der Signalpegel wird durch die Post Gain Steuerung nach Verstärkung und die Crossover Balance Regelung ausgesteuert EFX PEGEL SCHALTER 33 Über diesen Schalter wird der Betriebspegel der Effektschleife ausgewählt 10 dBV 3 V RMS in Ein Position low und 0 dBV 1 V RMS wenn in Aus Position high 3...

Page 17: ...17 ...

Page 18: ...priate Peavey catalog publication Bass Guitars Guitars Bass Amplification Guitar Amplification Sound Reinforcement Enclosures Microphones Keyboards DJ Lighting Mixers Powered Non Powered Accessories Cables Effects Processors Axcess Wear The Peavey Beat Monitor Magazine Key Issues Low Down PM Magazine ...

Page 19: ...arranties and the other terms and conditions expressed herein have been complied with Peavey will provide the necessary warranty service to repair or replace the product and will return it FREIGHT COLLECT to you the purchaser Peavey s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action including negligence is limited to the actual damages up to the...

Page 20: ...en so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings 15 This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit does not operate correctly d The unit has been dropped or the enclosure damaged 16 The user sho...

Reviews: