DC Current
Range
Accuracy
Resolution
2000 µA
± 1,0 % + 2 digit
1 µA
20 mA
10 µA
200 mA
± 1,2 % + 2 digit
100 µA
10 A
± 2,0 % + 2 digit
10 mA
Overload protection:
µA/mA-ranges: 0,5 A/600 V fuse
10A-ranges: 10A/600V fuse
maximum input current:
10 A
Resistance
Range
Accuracy
Resolution
200
Ω
± 0.8 % + 8 digit
0.1
Ω
2000
Ω
± 0.8 % + 2 digit
1
Ω
20 k
Ω
10
Ω
200 k
Ω
100
Ω
2000 k
Ω
± 1,0 % + 2 digit
1 k
Ω
Max. open circuit:
under 2,8 V
Overload protection: 250 V
rms
in all ranges (max. 15 sec.)
Battery Test
Range
Accuracy
Resolution
9 V
± 1,0 % + 2 digit
10 mV
1,5 V
1 mV
test current:
9V: 6 mA / 1,5 V: 100 mA
Diode Test
Range
Description
Test Conditions
Display read approx.
forward voltage of
diode
Forward DC current
1 mA.
Reversed DC voltage
approx. 2,8 V.
Continuity Check
Audible signal will sound if the resistance is less than approximately
30
.
-28-