37
7. After finishing the above adjustment, test running the lift with load. Run the lift with
Platforms in low position first, make sure the Platforms can rise and lower
synchronously and the Safety Device can lock and release synchronously. And then
test run the lift to the top completely. If there are anything improper, repeat the
above adjustment.
Circuit Diagram of Hydraulic System
Fig. 57
Remark: The Two-way valve No. 8 is specially for the optional power unit
drive rolling Jack model J6E only.
1. Filter
2. Gear pump
3.Cushion valve
4. Relief Valve
5. Motor
6. Throttle Valve
7.
Hydraulic
Solenoid Valve
8. Two-way Valve
9. Check valve
10. Cylinder For
Four-post lift
11. Cylinder For J6
N
O