7. 220V Wire connection and circuit diagram
7.1 Wire Connection diagram in the control box
(See Fig. 38)
.
7.2 220V Wire connection of hydraulic power unit
(See Fig. 39)
.
Motor wire (M1
、
M2) separately connected to two wires in the motor
Fig. 39
M2
Earth wire
M1
Fig. 38
Power wire
Wire
○
A
、
○
B
of limit switch
on cross beam
Wire of hydraulic solenoid valve
High limit switch Wire
○
C
Wire of motor
Air solenoid valve
Lower limit swit
ch
wire
○
D