Page 18
Start-Up Sequence
Before the generator is connected to the application, the generator
should be operated in isolation (i.e. not connected to the application)
for thirty minutes. This is to ensure any impurities present are purged
from the system. Failure to do this may harm the application.
Before connecting the generator to the mains and switching it on for the purge run, it is
necessary to fit the silencer to the nitrogen output port
Once this is done, the generator can be connected to the mains and switched on.
The Genius XE will then go through
Product Registration
. This is detailed on the next
page.
Continue to operate the generator for a further 30 minutes to allow all the internal pipe-
work and storage tanks will have been purged with Nitrogen.
The generator is now purged, the silencers can be removed and the tubes can be
connected at the rear of the unit.
CAUTION