1.5.2 Internal Wiring
Unless otherwise specified, electrical components operating range shall be 8.0 to 18.0 VDC. It is recommended that
the transmission controls solenoids are not engaged without the engine running. Transmission electrical components
should be fused separately from other vehicle components.
Electrical Connections
Two connections must be made to the transmission to interface with the TCM. The connections are for the transmission
control connector and the output speed sensor.
Figures 1.5.2-1 and 1.5.2-2 shows the internal system schematic.
CAV
Function
A
Shift SOL ‘A’
B
Shift SOL ‘B’
C
Line Pr
D
Line Pressure -
E
Sw12V
F
IMS A
G
IMS C
H
IMS B
J
IMS P
K
Turbine Speed +
L
Trans Temp Sensor
M
Trans Temp Sensor Ground
N
IMS Ground
P
R
Forward Clutch SOL
S
Reverse Clutch SOL
T
TCC SOL
U
TCC PWM
V
Turbine Speed
W
Neutral Safety
TCM Connector
Figure 1.5.2-1: TCM Connector and Terminal Locations