Manual
30
VM40MDB can archive all measurements ever recorded with the PCE-VM 40. They can also come from
different PCE-VM 40 units.
To search in larger amounts of data, there are filter functions on the right side of the header list. You may
search for a certain range of calendar dates, parts of the file
name or the content of the “place” field or for
the measurement mode. The wild-
card character “*” is allowed.
Select a record with the mouse pointer and click “Show”. A window showing “Properties” of the opened
file will appear.
You will find the following information:
-
Record name which was entered in the PCE-VM 40
-
Period of recording
-
Device name and serial number
-
Used standard with detailed settings
-
Record settings (triggers and interval)
-
Number of saved measurements, warnings and alarms (coloured)
-
Maximum values for X, Y and Z
You may manually enter a description of the place of measurement, measuring conditions, etc. Two text
fields are available for this purpose.
Click “Open protocol” to generate a report to DIN 4150-3, Appendix A. Under several menu tabs, the
necessary information is gathered. These include:
-
Purchaser and person in charge
-
Details about the source of vibration
-
Description of the monitored structure
-
Information about the location and the measuring point
-
Environmental and other conditions
-
Measuring results to be included
In the menu “Location and position”, pictures can be entered. Click inside the white space and load the
image file from a specified storage position.
Press “OK” to complete the report. The following figures show an example of such a report.
The header data of the report, including company address data and a logo, are entered
in the menu “File”
/ “Settings” of the main window.
Summary of Contents for PCE-VM 40A