Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to  the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Summary of Contents for PCE-AQD 10

Page 1: ...O2 Data Logger User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...ard to PC 6 8 Settings 6 8 1 SD card format 7 8 2 Setting the time 7 8 3 Setting the recording interval 7 8 4 Setting the beeper 8 8 5 Setting the decimal point 8 8 6 Setting the temperature unit 8 8...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...mperature Relative humidity CO2 0 50 C 10 90 RH 0 4000 ppm Resolution Temperature Relative humidity CO2 0 1 C 0 1 RH 1 ppm Accuracy Temperature Relative humidity CO2 0 8 C 4 of rdg 70 ppm 1000 ppm 5 o...

Page 5: ...pension brackets 3 8 Table stand 3 9 Battery compartment cover 3 10 Safety screw for battery compartment cover 3 11 RESET key 3 12 RS 232 output 3 13 SD card slot 3 14 9 V DC connection 3 15 CO2 senso...

Page 6: ...formatted Refer to chapter 8 1 for more information Note Please do not use an SD card formatted in another device e g digital camera In this case you have to format the SD card again in the data logge...

Page 7: ...wn the time key 3 3 for more than 2 seconds the following data appears in the display year month day hour minute second and the recording interval 6 4 SD card data structure 1 When you first insert th...

Page 8: ...e tester press the SET key 3 5 for more than 2 seconds This takes you to the setting menu and you can navigate through the menu with each further press of the SET key Sd F Format SD card dAtE Setting...

Page 9: ...Now you can move to the next value The sequence then is month day hour minute second Note The value to be set flashes 2 When you have set all the values and confirmed with the Enter key 3 2 all the s...

Page 10: ...ing the RS 232 interface 1 If the display shows rS232 you can use the key 3 3 and the key 3 4 to select yES or no where yES means that the RS 232 interface 3 12 is activated and no means that the inte...

Page 11: ...state This is done as follows While the machine is switched on press the RESET key 3 11 gently with a pointed object The machine is now reset to its original state 12 RS 232 PC interface The device h...

Page 12: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 13: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Reviews: