Introduction 

The PCE-AQD 10 is a data logger which records and saves the CO2 content, air temperature and 
relative  humidity.  The  data  is  stored  on  an  SD  card  (up  to  max.  16  GB  SDHC).  The  device  is 
mainly used for long-term recording in the food sector (refrigerated counters in department stores, 
refrigerated transport, warehouses) as well as for measurement and recording indoors (meeting 
rooms, offices, etc.)

 

 

 

measures temperature, humidity, CO2 

 

flexible internal real-time data storage via SD memory card (1 ... 16 GB) 

 

the saved data is saved directly to the SD card as an Excel file  

 

large LCD 

 

Specifications 

Measurement 
range 
- Temperature 
- Relative humidity 
- CO2

 

 
 

0 ... + 50 °C 

10 ... 90 % RH 

0 ... 4000 ppm

 

Resolution- 
- Temperature 
- Relative humidity 
- CO2

 

 

0.1 °C 

0.1 % RH 

1 ppm

 

Accuracy - 
- Temperature 
- Relative humidity 
- CO2

 

 

±0.8 °C 

±4 % of rdg.  

±70 ppm (<1000 ppm) 

±5 % of rdg. (<3000 ppm) 

±250 ppm (>3000 ppm) 

Measuring rate

 

5, 10, 30, 60, 120, 300 or 600 s or automatic  

(if the value is changed by ±1 °C, ±1 % RH or ±50 ppm, the data set is 

automatically saved to the memory)

 

Data memory

 

flexible via SD card memory 1 ... 16 GB 

(2 GB SD card included)

 

Display 

LCD, 60 x 50 mm 

Ambient 
temperature

 

0 ... +50 °C, <90 % RH

 

Power supply

 

6 x 1.5 V AAA battery (for time back-up only) / 9 V mains adaptor

 

Dimensions

 

132 x 80 x 32 mm

 

Weight 
(incl. battery)

 

285 g

 

 

Delivery scope 

CO2 data logger, 2 GB SD memory card, wall mounting kit, 6 x battery, mains adaptor and user 
manual

 

 

Available accessories: 

ISO calibration certificates (for temperature, humidity and CO2) 

 

 

Summary of Contents for PCE-AQD 10

Page 1: ...O2 Data Logger User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...ard to PC 6 8 Settings 6 8 1 SD card format 7 8 2 Setting the time 7 8 3 Setting the recording interval 7 8 4 Setting the beeper 8 8 5 Setting the decimal point 8 8 6 Setting the temperature unit 8 8...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...mperature Relative humidity CO2 0 50 C 10 90 RH 0 4000 ppm Resolution Temperature Relative humidity CO2 0 1 C 0 1 RH 1 ppm Accuracy Temperature Relative humidity CO2 0 8 C 4 of rdg 70 ppm 1000 ppm 5 o...

Page 5: ...pension brackets 3 8 Table stand 3 9 Battery compartment cover 3 10 Safety screw for battery compartment cover 3 11 RESET key 3 12 RS 232 output 3 13 SD card slot 3 14 9 V DC connection 3 15 CO2 senso...

Page 6: ...formatted Refer to chapter 8 1 for more information Note Please do not use an SD card formatted in another device e g digital camera In this case you have to format the SD card again in the data logge...

Page 7: ...wn the time key 3 3 for more than 2 seconds the following data appears in the display year month day hour minute second and the recording interval 6 4 SD card data structure 1 When you first insert th...

Page 8: ...e tester press the SET key 3 5 for more than 2 seconds This takes you to the setting menu and you can navigate through the menu with each further press of the SET key Sd F Format SD card dAtE Setting...

Page 9: ...Now you can move to the next value The sequence then is month day hour minute second Note The value to be set flashes 2 When you have set all the values and confirmed with the Enter key 3 2 all the s...

Page 10: ...ing the RS 232 interface 1 If the display shows rS232 you can use the key 3 3 and the key 3 4 to select yES or no where yES means that the RS 232 interface 3 12 is activated and no means that the inte...

Page 11: ...state This is done as follows While the machine is switched on press the RESET key 3 11 gently with a pointed object The machine is now reset to its original state 12 RS 232 PC interface The device h...

Page 12: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 13: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Reviews: