PBI DMN-2410D User Manual Download Page 10

 

 

DMM-2410D

 

 

Quad Channels Receiver and Processor 

Pro Broadband Inc. 

7.1 Overview of the Menu 

Users are advised to restore factory setting of the machine before the first time using it. Because of 

machine's too many functions, users are advised not to change those temporarily useless parameters in 

order to avoid unnecessary fault. 

After power on, the Local IP address will be shown on the LCD of DMM-1000CU. User can press ENTER 

key to get into the main menu. 

 

 

 

 

 

 

 

 

Status: show the status of the device. 

Configuration: Configure remux and TS/IP parameters. 

System: Configure the local settings of the device. 

 

7.2 Description of menu 

7.2.1 Status 

Main-Menu Sub-Menu1 

Sub-Menu2 

Sub-Menu3

Description 

Status 

Tuner Status  RSSI->Tuner 1/2/3/4 

Strength Display 

t

uner input signal Strength

 

C/N 

Display t

uner input signal C/N

 

Eb-No Display 

t

uner input signal Eb_No

 

BER Display 

t

uner input signal BER

 

Input Bit Rate 

T1/2/3/4 

 

Display tuner 1/2/3/4 input Bit rate 

IP 

 

Display TS IP input Bit rate 

Output Bit Rate  A1/2/3/4   

 

Display ASI-1/2/3/4 total and valid bit 

rate 

TS/IP Status 

Link Status 

 

Display IP link status: 

10M/100M/1000M/Disconnect 

Gigabit Output Status  

Display IP out status 

Gigabit In Status 

 

Display IP in status 

 

 

 

 

Summary of Contents for DMN-2410D

Page 1: ...P N 85E19 M0501 Rev A www pbi china com DMM 2410D Quad Channels Receiver and Processor User s Manual Brighten Your Digital View...

Page 2: ...Specifications 06 4 Order Information 06 5 Block Diagram 07 6 Front panel and rear panel instructions 07 7 Operation instructions using DMM 1000CU programmer 08 7 1 Overview of the Menu 08 7 2 Descrip...

Page 3: ...FOR EUROPEAN HARMONISED STANDARDS The CE mark which is attached to these products means it conforms to EMC Directive 89 336 EEC and Low Voltage Directive 73 23 EEC IMPORTANT INFORMATION Please retain...

Page 4: ...rflow into the unit Do not stand the product on soft furnishings or carpets Do not stack electronic equipment on top of the product Do not place the product in a location subject to extreme changes in...

Page 5: ...nd safe use of the device it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Wheneve...

Page 6: ...be remultiplexed for outputs 2 Features Variety of input options DVB T2 S2 S C T T2 and TS IP Built in TS re multiple er receives 4 Tuner and TS IP Output Dynamic PMT detection and automatic updating...

Page 7: ...ctor Type 4 x BNC female 75 Standard DVB ASI EN50083 9 Output Bit Rate 108Mb s TS over IP Connector Type 1 x RJ 45 100 1000 Base T Protocol UDP RTP Multicast Unicast IGMP V2 V3 Operation Mode 1 Simple...

Page 8: ...5V 12V supplied by DMM 1000MF or DMM 200MF chassis Power Consumption 15W Weight 560g Storage Temperature 10 to 55 Operating Temperature 0 to 45 Operating Humidity 10 to 90 non condensed 4 Order Inform...

Page 9: ...ions 7 Operation instructions using DMM 1000CU programmer NOTE The DMM 1000CU Programmer is an universal programmer unit for PBI DMM products family DMM 1000CU is a standalone product and not included...

Page 10: ...uration Configure remux and TS IP parameters System Configure the local settings of the device 7 2 Description of menu 7 2 1 Status Main Menu Sub Menu1 Sub Menu2 Sub Menu3 Description Status Tuner Sta...

Page 11: ...splayed only when the IP I O is configured as full duplex mode Bit Rate Output Bit Rate key in the bit rate of the newly generated MPTS valid range from 100K 216000 Kb s Packet Size 188 Byte 204 Byte...

Page 12: ...of the uni multicast IP input valid range from 1 65535 FEC Column UDP Port Port FEC Row UDP Port Port TS Clock Recovery Auto it is suggested to set Auto when there is accurate PCR carried by the input...

Page 13: ...l Machine Type MAC Address to Modify the MAC address S N display the serial number of the unit Gigabit MAC Address to Modify the Gigabit MAC address Detail Version Display the detail version of MCU FP...

Page 14: ...the host PC Then enter IP address of the module into the browser it will pop up a dialog asking for login user and password The default user name and password are root and 12345 The user name and pas...

Page 15: ...Brighten Your Digital View 13 www pbi china com Figure 8 3 Output Bitrate Figure 8 4 Tuner Status Figure 8 5 TS IP Status...

Page 16: ...LNB frequency Satellite Frequency Input downstream frequency of satellite Symbol Rate Input symbol rate of satellite LNB Voltage select the correct LNB voltage output of the F connector Off 13 V 18 V...

Page 17: ...on mode please refer to chapter System Device 8 3 1 1 Gigabit Out Under multiple output operation mode user can set output uni multicast IP address and port number for the built in remux and Tuner inp...

Page 18: ...de The pages below are displayed under Full duplex mode To change the TS IP operation mode please refer to System Device 8 3 2 1 Gigabit Out Under full duplex operation mode the device supports single...

Page 19: ...et Time To Live set TTL to the output IP packets Type of Service select the service type for the outputted IP streaming Uni Multi IP Address set the unicast or multicast IP address for the output IP s...

Page 20: ...lock Recover Auto it is suggested to set Auto when there is accurate PCR carried by the inputted TS IP Fixed Rate when fixed rate is selected user has to configure a bit rate to regenerate the TS cloc...

Page 21: ...l Channel Switch set up all IPTV channels status Note for Gigabit In and Gigabit local please refer to 8 1 1 and 8 2 1 8 4 Remux The device supports one DVB TS remux via Tuner In or TS IP In available...

Page 22: ...l information of this device including device name serial number software version and so on User can implement the alarm switch configuration network settings TS IP operation mode and software upgrade...

Page 23: ...PTV The device will reboot after change 8 5 2 System IP Control The network settings for the device can be found and configured under the page below IP Address set the device s IP address Network Mask...

Page 24: ...in Set the login ID and password for the web management server of the device 8 5 5 System Factory Default Click the button Default to restore the factory default settings to the device Note the IP add...

Page 25: ...ten Your Digital View 23 www pbi china com 8 5 6 System System Reboot User can reboot this device by clicking the button Reboot 8 5 7 System Upgrade User can upgrade software of this device via Web br...

Page 26: ...ous accident z Fix the front and rear covers onto the DMM 1100MF or DMM 210MF z Connect all input output cables and Ethernet cables z Plug the power cable into DMM 1100MF or DMM 210MF The POWER Indica...

Page 27: ...No 3 FengZhi East Road XiBei Wang Town Hai Dian District Beijing 100094 China Tel 86 0 10 57802000 Fax 86 0 10 57802016 Mail mkt pbicn com sales pbicn com...

Reviews: