TO THE  INSTALLER:

This manual is the property of the owner and must be affixed near the boiler
for future reference.

TO THE  OWNER: 

This boiler should be inspected annually by a Qualified Service Agency.

TO BE COMPLETED BY THE INSTALLER

Service Agency

Phone No.

Address

Boiler Model No.  

Serial No.

Date of Installation:

If the information in this manual is not
followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.

– Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

–  WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch;

do not use any phone in your
building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

– Installation and service must be

performed by a qualified installer,
service agency or the gas supplier.

– Ne pas ranger ou utiliser de la gazoline ou

d’autres liquides ou gaz inflammables à
proximité de cet appareil ou d’un autre du
même type.

– QUE FAIRE SI VOUS DÉTECTEZ UNE 

ODEUR DE GAZ

• Ne pas tenter d’allumer l’appareil.
• Ne toucher à aucun interrupteur

électrique ; n’utiliser aucun appareil
téléphonique dans l’immeuble.

• Contacter immédiatement votre fournisseur

de gaz à partir du téléphone d’un voisin.
Suivre les instructions données par votre
fournisseur de gaz.

• S’il est impossible de rejoindre le

fournisseur de gaz, appeler le service 
des incendies.

– L’installation et l’entretien doivent être

effectués par un installateur qualifié, une
société d’entretien ou le fournisseur de gaz.

PB HEAT, LLC

131 S. CHURCH ST • BALLY, PA 19503

TT8067 R3 (11/14-3M)

Printed in U.S.A.

©2014 PB Heat, LLC. All rights reserved.

WARNING

Négliger de suivre ces instructions à la
lettre pourrait provoquer un incendie ou
une explosion causant des dégâts
matériels, des blessures ou la mort.

MISE EN GARDE

Summary of Contents for SERIES 63

Page 1: ...plier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Ne pas ranger ou utiliser de la gazoline ou d autres liquides ou g...

Page 2: ...ion resumes automatically when the system pressure falls below the CUT IN pressure 1b Limit Water Boiler An electrical device that automatically interrupts the boiler operation when the water temperat...

Page 3: ...relief valve can discharge a large amount of steam or hot water the installer should provide piping to discharge water near the floor close to a floor drain If the safety relief valve discharges water...

Page 4: ...4 Figure 2 Sequence of Operation Intermittent Pilot...

Page 5: ...5 Figure 3 Operating Instructions Spark Ignition 63 03 thru 64 08 Natural Gas LP Gas 64 09 thru 64 12 LP Gas...

Page 6: ...Figure 4 Operating Instructions Spark Ignition 63 03 thru 64 08 Natural Gas LP Gas 64 09 thru 64 12 LP Gas...

Page 7: ...ace control access panel if applicable 10 Turn on all electrical power to the appliance 11 Set thermostat or operating control to desired setting 12 If the appliance will not operate follow the instru...

Page 8: ...r a NIOSH MSHA approved respirator Wear long sleeved loose fitting clothing and gloves to prevent skin contact Wear eye goggles Minimize airborne dust prior to handling and removal by water misting th...

Page 9: ...ontinuous to chimney with no separations obstructions or sags Vent pipe must be supported at minimum 4 foot intervals and secured with sheet metal screws 2 The vent system must not have signs of conti...

Page 10: ...Inspection and Maintenance Annual For continued safe operation a qualified service agency must provide a more detailed inspection of burners heat exchanger and vent system and provide maintenance as s...

Reviews: