When you copy this field into another field, the maximum number
of characters for the final field is
2710 (
or
0-100
for 9403). Allow
only as many characters as you need, because extra characters
use up space. Also, if you are copying into a bar code field, the
maximum number of characters in the destination bar code is
determined by the bar code specification (UPCA-12, EAN-13,
etc.). You need to apply field options to manipulate the text
entered in this field. For example, you may want to copy data
from this field into another field. See "Option 4 Copy Data" in
Chapter 5 for more information.
In the following example, data is entered into four non-printable
fields and merged to form field 5, and is then printed as a bar
code. See "Merging Fields" in Chapter 5 for more information.
Field
Data
Field Type
1
20374
Non-printable
2
339
Non-printable
3
8
Non-printable
4
15
Non-printable
5
20374339815
Bar Code
Each non-printable text field requires a separate definition.
Syntax
D,field#,# of char
p
D1. D
Non-Printable Text Field.
D2. field#
Unique number from
0-999
assigned to this field.
Maximum number of characters in this field:
0-2710
.
D,4,20
p
Defines a non-printable text field (field #4) with a maximum of 20
characters.
Defining Fields
4-13
Summary of Contents for Monarch 9412
Page 8: ...vi Table of Contents ...
Page 14: ...1 6 Getting Started ...
Page 22: ...2 8 Designing a Format ...
Page 70: ...4 22 Defining Fields ...
Page 88: ...5 18 Defining Field Options ...
Page 98: ...6 10 Printing ...
Page 143: ...Samples A 9 ...
Page 146: ...A 12 Samples ...
Page 166: ...C 12 Symbol Sets Code Pages ...
Page 169: ...B a t c h W o r k s h e e t Format Design Tools D 3 ...
Page 170: ...C h e c k D i g i t W o r k s h e e t D 4 Format Design Tools ...
Page 183: ......
Page 184: ......