290
Action must be
0
(disable) or
1
(enable) for the
backfeed control packet or the printer is active.
291
Dispense position must be
50
to
200
dots and the
backfeed distance is greater than the dispense position
or the printer is active.
292
Backfeed distance must be
10
to
200
dots or the printer
is active.
310
Check digit scheme number must be
1
to
10
.
311
Modulus must be
2
to
11
.
314
Check digit algorithm must be
D
(sum of digits) or
P
(sum of products).
325
Duplicating direction must be
0
(insert after) or
1
(insert
before) in duplicate fields for graphics.
327
Amount of row adjustment must be
0
to
999
(
0
to
99
for
9403) dots in duplicate fields for graphics.
328
Duplicate count must be
0
to
999
(
0
to
99
for 9403).
340
Bitmap line encoding must be
H
(hex) or
R
(run length).
350
Font selector must be
1
to
9999
.
351
Font data length must be
68
to
16384
.
352
Insufficient font memory is available for the downloaded
font.
380
Job request is outside the range
0
to
4
.
400
The character immediately following
{
is invalid.
402
Field separator is not in the expected location.
403
Field separator was not found.
Errors
9-9
Summary of Contents for Monarch 9412
Page 8: ...vi Table of Contents ...
Page 14: ...1 6 Getting Started ...
Page 22: ...2 8 Designing a Format ...
Page 70: ...4 22 Defining Fields ...
Page 88: ...5 18 Defining Field Options ...
Page 98: ...6 10 Printing ...
Page 143: ...Samples A 9 ...
Page 146: ...A 12 Samples ...
Page 166: ...C 12 Symbol Sets Code Pages ...
Page 169: ...B a t c h W o r k s h e e t Format Design Tools D 3 ...
Page 170: ...C h e c k D i g i t W o r k s h e e t D 4 Format Design Tools ...
Page 183: ......
Page 184: ......