Page 40
INPUTS MENU
INPUT N (PARAMETERS)
Message
Description
Type Units Default
Range
Fieldbus
address
In 1÷2 function
Function associated with input 1
÷ 2. (*)
Selection
0
[0] NONE
[1] ZERO
[2] TARE
[3] DEL. TARE
[4] PRINT
[5] RES.AL.
[6] START
[7] PAUSE
[8] RESTART
[9] STOP
[10] SEL. N/L
1401
1402
[…]
In 3÷6 function
Function associated with input 3
÷ 6. (*)
Selection
0
[0] NONE
[1] ZERO
[2] TARE
[3] DEL. TARE
[4] PRINT
[5] RES.AL.
[6] START
[7] PAUSE
[8] RESTART
[9] STOP
[10] SEL. N/L
[11] SEL. REC. (
**
)
1403
…
1406
(
**
) (**) The “SEL. REC.” selection is only available for inputs 3, 4, 5 and 6.
(*) One of the following functions can be associated with each logical input:
• Zero:
It performs zero calibration.
• Tare:
It performs auto tare.
• Del. Tare:
It deletes the tare.
• Print:
It prints the weight.
• Alarm reset:
It resets the alarm condition.
• Start:
Batching start command.
• Pause:
Batching pause command.
• Restart:
Batching restart command, following a batching pause command or following a blackout.
• Stop:
Batching stop command (the input must be kept ON for the number of seconds set in the
batching parameter “Batch. Stop Timer”).
• Net/gross weight selection:
It switches weight display (net/gross weight).
• Recipe selection:
Selection of the active recipe; function available only for inputs 3, 4, 5 and 6.
Where the input 3 represents the least significant bit and the input 6 the most significant bit of the
selection (i.e. Input 3 ON + Input 4 ON + Input 5 OFF + Input 6 OFF = recipe 3).