Page 37
Cycle end output
Output associated with the end of
a batching cycle. "NA” operating
logic, it is activated at the end of
the last phase of the batching cycle
and remains ON for the cycle end
time (settable parameter). In the
case of a parameter set to 0, no
output is associated.
Numeric setup
0
0÷32
0118
Alar
m
output
This output activates in an alarm
condition ("NA” operating logic). In
the case of a parameter set to 0, no
output is associated.
Numeric
setup
0
0÷32
0119
Timer mode
This parameter allows to select the
unit of measurement of the time for
the TIMER activity.
Selection
0
[0] SECONDS
[1] MINUTES
0120
Batching Stop T
imer
Value in seconds that indicates how
long it should be kept the STOP
command (both from touchscreen
that by logic input) to ensure that
the batching is interrupted.
Numeric
setup
3
0.0 ÷ 10.0
0121
Batching star
t tare
Autotare execution selection at the
beginning of the batching.
Selection
OFF
[0] OFF
[1] ON
0151
Print Batch.
Automatic print selection at the end
of each batching cycle.
Selection
OFF
[0] OFF
[1] ON