TABLE RELATING TO THE CODING OF THE STATUS REGISTER
Bit
15
14
13
12
11
10
9
8
Description
Setup
(***)
Weight
delta
Output 2 Output 1
Input 2
Input 1
Run
Backup
Hold
function
Bit
7
6
5
4
3
2
1
0
Description
Not
calibrated
Weight
error
Over-load
Under-
load
Tare
entered
Zero
band
Peso
stabile
Centro di
zero
TABLE RELATING TO THE CODING OF THE KEYBOARD BLOCK
Bit
15-4
3
2
1
0
Description
Not used
SET key
enables
FUN
key enables
—>0<—
key enables
PRG
key enables
TABLE RELATING TO THE CODING OF THE DIGITAL INPUTS/OUTPUTS
Bit
15-2
1
0
Description
Not used
IN/OUT 2 enables
IN/OUT 1
enables
TABLE RELATING TO THE CODING OF THE DIVISION AND DECIMAL VALUES
Address
Description
Accepted values
1101
Division value
1 - 2 - 5 - 10 - 20 - 50
1102
Number of decimals
0 - 1 - 2 - 3 - 4
TABELE RELATED TO THE CODING OF THE COMMAND REGISTER / DATA REGISTER
Register value
COMMAND REGISTER FUNCTION
DATA REGISTER FUNCTION
0x0001
Semi-automatic zero
-
0x0002
Automatic tare
-
0x0003
Cancel peak
-
0x0004
Zero calibration (**)
-
0x0005
Sample weight calibration (**)
Sample weight value in MSB and LSB
0x0006
Analog test
Value between 0 and 100 in intervals of 10
in LSB
0x0007
Saving data in permanent memory
-
0x000A
Command to weigh
-
0x000B
Switching command from gross to net weight
-
0x000C
Switching command from net to gross weight
-
0x000D
Capture of zero signal (table calibration)
-
0x3FFF
Enabling the Output Data Area reading (*)
-
(*) This command must be sent each time the registers are changed in the Fieldbus Output Data Area, in order that
the changes are effective in the device. Caution. When the device is switched on, the Output Data Area is completely
zeroed, so the Fieldbus master must read the parameter values from the Input Data Area and copy them to the relevant
Output Data Area registers, before sending the reading enabling command 0x3FFF to the Command Register. Other-
wise, all the parameters managed in the Output Data Area would be reset. Do not use in case of CANopen fieldbus.
(**) Function available only in the case of FREE operation or in case of METRIC operation with enabled calibration jumper.
(***) The device is in the setup phase (TRUE flag during access to the SETUP menu of the device).