3. AUTOTARE COMMAND
MASTER:
<Ind> “A” EOT
DEVICE:
<Ind> “A” ACK EOT
or
<Ind> NAK EOT
4. SEMI-AUTOMATIC ZERO COMMAND
MASTER:
<Ind> “Z” EOT
DEVICE:
<Ind> “Z” ACK EOT
or
<Ind> NAK EOT
5. PEAK VALUE RESET COMMAND
MASTER:
<Ind> “X” EOT
DEVICE:
<Ind> “X” ACK EOT
or
<Ind> NAK EOT
6. PROGRAMMING OF TWO WEIGHT THRESHOLDS
MASTER:
<Ind> “S” <s1> <s2> ETX <csum> EOT
DEVICE:
<Ind> “S” ACK EOT
or
<Ind> NAK EOT
I valori di soglia devono essere inferiori al parametro fondo scala.
7. REQUEST FOR PROGRAMMED THRESHOLDS
MASTER:
<Ind> “R” EOT
DEVICE:
<Ind> “R” <s1> <s2> ETX <csum> EOT or
<Ind> NAK EOT
8. ACTIVATION OF LOGIC OUTPUTS
MASTER:
<Ind> “U” <output> EOT
DEVICE:
<Ind> “U” ACK EOT
or
<Ind> NAK EOT
9. REQUEST FOR LOGICAL INPUTS STATUS
MASTER:
<Ind> “I” EOT
DEVICE:
<Ind> “I” <input> ETX <csum> EOT
or
<Ind> NAK EOT
10. COMMAND TO SAVE THE THRESHOLDS IN PERMANENT MEMORY
MASTER:
<Ind> “E” EOT
DEVICE:
<Ind> “E” ACK EOT
or
<Ind> NAK EOT
<set1>
e
<set2>
: formatted as a <weight> field
<uscite>
e
<ingressi>
: 1 ASCII character encoded as per the table (bit = 1 if input or output ON)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
0
1
1
0
0
In 2
Out 2
In 1
Out 1
delta).
• Gross weight equal to or greater than the minimum weigh (20 divisions) and less than the maximum
capacity.
• Net weight not null.