EN.FBUS.
Enabling
Fieldbus
Enabling Profibus fieldbus; if OFF,
no error message regarding the
Ethernet/IP communication is
displayed
Sel.
OFF
OFF
ON
IP
IP Address
Protocol IP address Ethernet/IP
Com.
0.0.0.0
0.0.0.0
÷
255.255.255.255
SUBNET.
Subnet Mask Subnet Mask Ethernet/IP protocol Com.
0.0.0.0
0.0.0.0
÷
255.255.255.255
INP.REG.
Dimension
Input area
Dimension of the input area
for Ethernet/IP fieldbus (values
expressed in bytes)
Sel.
128
32, 64, 96, 128
OUT.REG.
Dimension
Output area
Dimension of the input area
for Ethernet/IP fieldbus (values
expressed in bytes).
Sel.
128
32, 64, 96, 128
The
EDS
configuration file
“HILSCHER NIC 50-RE EIS V1.1.EDS”
is provided. The size of the input and output areas
set in the PLC (default input area of 128 bytes, default output area of 128 bytes) must match the size of the input and