The following table lists the registers of the output area (written by the master and captured by the device), common to
all PROFINET, ETHERCAT, ETHERNET/IP, PROFIBUS and DEVICENET. fieldbuses.
The registers have a size of 16 bits. The registers written by the master in the output area are read by the device at a
maximum frequency of 125 Hz (80 Hz in the case of PROFIBUS fieldbus).
The size of the output area set in the fieldbus master must coincide with the dimension set in the instrument.
Addr
INPUT AREA REGISTER
Note
0
Command Register
See the relevant table
1
Data Register (MSB)
Value INT. - Most significant word (See the relevant table)
2
Data Register (LSB)
Value INT. Less significant word (See the relevant table)
3
Monitor register
Value is copied into the equivalent register in the input area.
4
Set-Point 1 (MSB)
Value INT. - Most significant word
5
Set-Point 1 (LSB)
Value INT. - Less significant word
6
Set-Point 2 (MSB)
Value INT. - Most significant word
7
Set-Point 2 (LSB)
Value INT. - Less significant word
8
Load cell capacity (MSB) (*)
Value INT. - Most significant word
9
Load cell capacity (LSB) (*)
Value INT. - Less significant word
10
Cell 1 sensitivity (*)
Value INT.
11
Cell 2 sensitivity (*)
Value INT.
12
Cell 3 sensitivity (*)
Value INT.
13
Cell 4 sensitivity (*)
Value INT.
14
Cell 5 sensitivity (*)
Value INT.
15
Cell 6 sensitivity (*)
Value INT.
16
Cell 7 sensitivity (*)
Value INT.
17
Cell 8 sensitivity (*)
Value INT.
18
Weight division value (*)
See the relevant table
19
Decimals (*)
20
Fixed tare (MSB) (*)
Value INT. - Most significant word
21
Fixed tare (LSB) (*)
Value INT. - Less significant word
22
Standby function
Value INT.
23
Keyboard block function
See the relevant table.
24
Password function
Value INT.
25
Peak function
See match on page 10
26
Datalogger function
See match on page 10
27
Datalogger Trigger
See match on page 10
28
Datalogger frequency
See match on page 10
29
Filter factor
See match on page 13
30
Output rate ADC
See match on page 13
31
Average reading number
Value INT.
32
Monotony time
Value INT.
33
Oscillation time
Value INT.
34
Oscillation range
Value INT.
35
Full scale (MSB) (*)
Value INT. - Most significant word
36
Full scale (LSB) (*)
Value INT. - Less significant word
37
Weight stability (*)
See match on page 13
38
Autozero upon power up (MSB) (*)
Value INT. - Most significant word
39
Autozero upon power up (LSB) (*)
Value INT. - Less significant word
40
Tracking of zero (*)
See match on page 13
41
Divisions that can be reset (Key >0<) (LSB) (*)
Value INT.
42
Function of input 1
See match on page 14
43
Function of input 2
See match on page 14
44
Mode of output 1 - Function
See match on page 14