39
[Gas pipe sizing tables]
• These tables are for reference only. Consult gas pipe manufacturer for actual pipe capacities.
• It is an example of Schedule 40 Metallic Pipe.
• (Only Table 1 - 4)
Values in Table are in ft
3
of Gas per Hour. Contact your gas supplier for Btu/ft
3
ratings. For simplification
of your calculations, 1 ft
3
of Gas is approximately equivalent to 1,000 Btu.
1. Maximum Natural Gas Delivery Capacity (For Less than 6 in. W.C. initial supply pressure)
0.5 in. W.C. Pressure Drop
Pipe Size
Length (including fittings)
10 ft
20 ft
30 ft
40 ft
50 ft
60 ft
70 ft
80 ft
90 ft
100 ft 125 ft 150 ft 175 ft 200 ft
(3 m)
(6 m)
(9 m) (12 m) (15 m) (18 m) (21 m) (24 m) (27 m) (30 m) (38 m) (45 m) (53 m) (60 m)
1/2 in.
172
118
95
81
72
65
60
56
52
50
44
40
37
34
3/4 in.
360
247
199
170
151
137
126
117
110
104
92
83
77
71
1 in.
678
466
374
320
284
257
237
220
207
195
173
157
144
134
1 1/4 in.
1,390
957
768
657
583
528
486
452
424
400
355
322
296
275
1 1/2 in.
2,090 1,430 1,150
985
873
791
728
677
635
600
532
482
443
412
2 in.
4,020 2,760 2,220 1,900 1,680 1,520 1,400 1,300 1,220 1,160 1,020
928
854
794
2 1/2 in.
6,400 4,400 3,530 3,020 2,680 2,430 2,230 2,080 1,950 1,840 1,630 1,480 1,360 1,270
2. Maximum Natural Gas Delivery Capacity (For 6 - 7 in. W.C. initial supply pressure)
1.0 in. W.C. Pressure Drop
Pipe Size
Length (including fittings)
10 ft
20 ft
30 ft
40 ft
50 ft
60 ft
70 ft
80 ft
90 ft
100 ft 125 ft 150 ft 175 ft 200 ft
(3 m)
(6 m)
(9 m) (12 m) (15 m) (18 m) (21 m) (24 m) (27 m) (30 m) (38 m) (45 m) (53 m) (60 m)
1/2 in.
250
172
138
118
105
95
87
81
76
72
64
58
53
50
3/4 in.
524
360
289
247
219
199
183
170
160
151
134
121
111
104
1 in.
986
678
544
466
413
374
344
320
300
284
252
228
210
195
1 1/4 in.
2,030 1,390 1,120
957
848
768
707
657
617
583
516
468
430
400
1 1/2 in.
3,030 2,090 1,680 1,430 1,270 1,150 1,060
985
924
873
774
701
645
600
2 in.
5,840 4,020 3,230 2,760 2,450 2,220 2,040 1,900 1,780 1,680 1,490 1,350 1,240 1,160
2 1/2 in.
9,310 6,400 5,140 4,400 3,900 3,530 3,250 3,020 2,840 2,680 2,380 2,150 1,980 1,840
3. Maximum Natural Gas Delivery Capacity (For 7 - 8 in. W.C. initial supply pressure)
2.0 in. W.C. Pressure Drop
Pipe Size
Length (including fittings)
10 ft
20 ft
30 ft
40 ft
50 ft
60 ft
70 ft
80 ft
90 ft
100 ft 125 ft 150 ft 175 ft 200 ft
(3 m)
(6 m)
(9 m) (12 m) (15 m) (18 m) (21 m) (24 m) (27 m) (30 m) (38 m) (45 m) (53 m) (60 m)
1/2 in.
364
250
201
172
153
138
127
118
111
105
93
84
77
72
3/4 in.
762
524
420
360
319
289
266
247
232
219
194
176
162
151
1 in.
1,440
986
792
678
601
544
501
466
437
413
366
332
305
284
1 1/4 in.
2,950 2,030 1,630 1,390 1,230 1,120 1,030
957
898
848
751
681
626
583
1 1/2 in.
4,420 3,030 2,440 2,090 1,850 1,680 1,540 1,430 1,350 1,270 1,130 1,020
938
873
2 in.
8,500 5,840 4,690 4,020 3,560 3,230 2,970 2,760 2,590 2,450 2,170 1,970 1,810 1,680
2 1/2 in. 13,600 9,310 7,480 6,400 5,670 5,140 4,730 4,400 4,130 3,900 3,460 3,130 2,880 2,680
4. Maximum Natural Gas Delivery Capacity (For 8 - 10.5 in. W.C. initial supply pressure)
3.0 in. W.C. Pressure Drop
Pipe Size
Length (including fittings)
10 ft
20 ft
30 ft
40 ft
50 ft
60 ft
70 ft
80 ft
90 ft
100 ft 125 ft 150 ft 175 ft 200 ft
(3 m)
(6 m)
(9 m) (12 m) (15 m) (18 m) (21 m) (24 m) (27 m) (30 m) (38 m) (45 m) (53 m) (60 m)
1/2 in.
454
312
250
214
190
172
158
147
138
131
116
105
96
90
3/4 in.
949
652
524
448
397
360
331
308
289
273
242
219
202
188
1 in.
1,790 1,230
986
844
748
678
624
580
544
514
456
413
380
353
1 1/4 in.
3,670 2,520 2,030 1,730 1,540 1,390 1,280 1,190 1,120 1,060
936
848
780
726
1 1/2 in.
5,500 3,780 3,030 2,600 2,300 2,090 1,920 1,790 1,680 1,580 1,400 1,270 1,170 1,090
2 in.
10,600 7,280 5,840 5,000 4,430 4,020 3,700 3,440 3,230 3,050 2,700 2,450 2,250 2,090
2 1/2 in. 16,900 11,600 9,310 7,970 7,070 6,400 5,890 5,480 5,140 4,860 4,300 3,900 3,590 3,340
5. Maximum Undiluted Propane (LP) Delivery Capacity in Thousands of Btu/h
0.5 in. W.C. Pressure Drop
Pipe Size
Length (including fittings)
10 ft
20 ft
30 ft
40 ft
50 ft
60 ft
80 ft
100 ft
125 ft
150 ft
175 ft
200 ft
(3 m)
(6 m)
(9 m)
(12 m)
(15 m)
(18 m)
(24 m)
(30 m)
(38 m)
(45 m)
(53 m)
(60 m)
1/2 in.
291
200
160
137
122
110
101
94
89
84
74
67
3/4 in.
608
418
336
287
255
231
212
197
185
175
155
140
1 in.
1,150
787
632
541
480
434
400
372
349
330
292
265
1 1/4 in.
2,350
1,620
1,300
1,110
985
892
821
763
716
677
600
543
1 1/2 in.
3,520
2,420
1,940
1,660
1,480
1,340
1,230
1,140
1,070
1,010
899
814
2 in.
6,790
4,660
3,750
3,210
2,840
2,570
2,370
2,200
2,070
1,950
1,730
1,570