71
Shutdown Instructions
1. Stop any water demand.
2. Turn off the electrical power.
3. Turn the gas control manual valve clockwise to
the off position.
This Combi Boiler does not have a pilot. It is
equipped with an ignition device that automatically
lights the burner.
Do not try to light the burner by hand.
1. Read the safety information in the installation
manual or on the front of the Combi Boiler
2. Turn off all electrical power to the Combi Boiler.
3. Do not attempt to light the burner by hand.
4. Turn the gas control manual valve (external to
the Combi Boiler) clockwise to the off position.
5. Wait five minutes to clear out any gas. If the
smell of gas remains, stop, and follow the
instructions on page 3 of Owner's Guide.
6. Turn the gas control manual valve
counterclockwise to the on position.
7. Turn on the electrical power to the Combi Boiler.
8. The Combi Boiler will now operate whenever
hot water is called for. If the Combi Boiler will
not operate, follow the shutdown instructions
and call a service technician.
A fire or explosion may result if these
instructions are not followed, which may cause
lose of life, personal injury or property damage.
WARNING