Saving the configuration
35
3088/I Getting Started Guide
5 • System Management
Saving the configuration
To save all configuration changes into non-volatile memory, click on the hyperlink
Save Configuration
in the
System Management
menu item. Click on the
Save
button and wait until you see the message that verifies the
save was executed properly.
Figure 20. Saving the configuration to non-volatile memory
Reset for Factory Default
To recover from a forgotten password, the user may reset the unit to its factory configuration. Click on the
Reset
hyperlink in the
System Management
menu. If you want to reset to factory default settings, check the box
for that function. (See
figure 21
.) Click on the
Restart
button. Wait until the 3088/I has completely restarted
before doing anything. At this point, you should return to the console port since the IP address also returns to
its default setting. (See the next section.)
Figure 21. Resetting the 3088/I to factory default
Console
The 3088/I offers a console command line interface. The terminal emulator should be configured to 9600 bps/
1 stop bit/ no parity/ XON-XOFF flow control. This is typically used when doing the initial configuration of
the IP address and subnet mask. (See also
“Configure the IP address”
on page 17.)
Summary of Contents for RocketLink-G 3088/I
Page 7: ...7 3088 I Getting Started Guide Table of Contents RS 232 console interface pin assignments 61...
Page 9: ...9 List of Tables 1 General conventions 13...
Page 14: ...14 Chapter 1 General information Chapter contents RocketLink G 3088 I overview 15 Features 15...
Page 56: ...56 Appendix D RJ 11 non shielded DSL port Chapter contents RJ 11 non shielded DSL port 57...