4.0  INSTALLATION

The Patton Model 2029 is very simple to install.  Once you have

configured the DIP switches, just plug it in like a normal cable and
you're ready to go.  Figure 3 illustrates the proper connections for the
standard cables.  If you have special-ordered a non-standard
connector, your connections may be different.

7

Figure 3.  Installing the Model 2029

Model 2029

PC

Printer

5.0  OPERATION

Once your interface converter is properly configured and installed,

it should operate transparently—as if it were a standard cable
connection.  Operating power is derived from the RS-232 data and
control signals; there is no “ON/OFF” switch.  

5.1  LED  STATUS MONITORS

The Model 2029 features an easy-to-read status LED that glows

red to indicate the condition of the transmission line.  Figure 1 shows
the location of the LED.  The following chart describes the LED's
various functions.

The red LED indicator blinks to show data activity.  However, since

there is only one indicator, it uses different LED codes to demonstrate
various messages.  The following chart describes these codes:

8

LED Codes

●  ●  

●  

———

●  ●  

●  

———

Computer is sending data

●  

———

●  

———

●  

———

Serial device is connected; computer is 

not sending data

●  ●  

———

●  ●  

———

Both serial and parallel devices are

connected; computer not sending

data

Key:

Blink

Short pause

———

Long pause

Summary of Contents for 2029

Page 1: ...lel to Serial Serial to Parallel Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2029 B Rev C Doc 102011UB Revised 6 16 09 C E R T I F I E D An...

Page 2: ...d used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 2029 has been tested and found to comply with the l...

Page 3: ...ontainer This number may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted...

Page 4: ...S A 2 2 DESCRIPTION The Patton Model 2029 Parallel to Serial Converter automatically converts RS 232C serial data to parallel data format and vice versa Incorporating advanced microprocessor technolo...

Page 5: ...open the case for configuration The configuration switches allow you to select data rates parity word length and flow control selection The following section describes all switch locations positions a...

Page 6: ...e flow control Switch 2 Enable Disable the LED Indicator The setting for Switch 2 determines whether the LED indicator is enabled or disabled 5 Flow Control SW1 Hardware OFF Software ON LED SW2 ON ON...

Page 7: ...termine the frequency and data rate The following chart shows the settings that may be used 6 300 OFF OFF ON 600 ON OFF ON 1200 ON ON OFF 2400 OFF ON ON 4800 ON ON ON 9600 OFF OFF OFF 19200 ON OFF OFF...

Page 8: ...the DIP switches just plug it in like a normal cable and you re ready to go Figure 3 illustrates the proper connections for the standard cables If you have special ordered a non standard connector you...

Page 9: ...o indicate the condition of the transmission line Figure 1 shows the location of the LED The following chart describes the LED s various functions The red LED indicator blinks to show data activity Ho...

Page 10: ...gral cable Data Rates 0 38 400 Kbps LED LED displays status and operating condition Power Supply No external power required uses power from RS 232 interface Data Format 7 or 8 bits 1 or 2 stop bits ev...

Page 11: ...DB 9 Interface Strobe Output 1 Data bit 0 I O 2 Data bit 1 I O 3 Data bit 2 I O 4 Data bit 3 I O 5 Data bit 4 I O 6 Data bit 5 I O 7 Data bit 6 I O 8 Data bit 7 I O 9 Acknowledge Input active low 10 B...

Page 12: ...An Certi APPENDIX C PATTON MODEL 2029 BLOCK DIAGRAM Copyright Patton Electronics Company All Rights Reserved 11...

Reviews: