background image

2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

•  Converts parallel data to serial data and vice versa
•  Automatically selects parallel-to-serial and serial-to-parallel

operation

•  Serial data rates to 38,400 bps
•  No AC power required
•  Supports both software and hardware flow control
•  A five-state LED monitors status and diagnostics
•  Ultra-miniature size
•  A DB-9 female and a Centronics male connector
•  Made in the U.S.A.

2.2  DESCRIPTION

The Patton Model 2029 Parallel to Serial Converter

automatically converts RS-232C serial data to parallel data format and
vice versa.  Incorporating advanced microprocessor technology, the
Model 2029 is able to automatically sense and select parallel and serial
modes.  Requiring no AC power, the Model 2029 supports serial data
rates to 38.4 Kbps.

For easy configuration, the Model 2029 features a convenient set

of external configuration switches.  These accessible configuration
switches allow the user to control baud rate, parity, word length and
flow control.  An easy-to-read LED indicator displays status and
operating condition.

Housed in an ultra-miniature ABS plastic case, the Model 2029

measures only 2.68” x 1.25” x .75”.  The Patton Model 2029 comes
equipped with a DB-9 female connector on the serial side and a
Centronics 36 pin male connector on the parallel side.  A 6-foot integral
cable is also included.

3

3.0  CONFIGURATION

The Model 2029 is simple to install and designed for excellent

reliability.  The following instructions will help you set up and install the
converter properly.  If you have any questions, please call Patton
Technical Support at (301) 975-1007.

3.1  CONFIGURATION SWITCHES

The Model 2029 uses a set of eight external DIP switches (see

Figure 1) that allow configuration to a wide range of applications.
Because all eight switches are in one externally accessible DIP switch
package, there is no need to open the case for configuration.  The
configuration switches allow you to select data rates, parity, word length
and flow control selection.  The following section describes all switch
locations, positions and functions.

The Model 2029 uses a 

miniature configuration switch package.

To configure your unit, use a small screwdriver and gently push each
switch to its proper setting.  The ON and OFF positions are shown in
Figure 2.  Default settings for the DIP switches are shown in the table
on the following page.  Detailed settings follow the table.

4

Figure 1. The location of the configuration switches

Figure 2. The miniature configuration switch package

OFF

1 2 3 4 5 6 7 8

DHS-8

Configuration

Switch

Complete

Status LED

Summary of Contents for 2029

Page 1: ...lel to Serial Serial to Parallel Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2029 B Rev C Doc 102011UB Revised 6 16 09 C E R T I F I E D An...

Page 2: ...d used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 2029 has been tested and found to comply with the l...

Page 3: ...ontainer This number may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted...

Page 4: ...S A 2 2 DESCRIPTION The Patton Model 2029 Parallel to Serial Converter automatically converts RS 232C serial data to parallel data format and vice versa Incorporating advanced microprocessor technolo...

Page 5: ...open the case for configuration The configuration switches allow you to select data rates parity word length and flow control selection The following section describes all switch locations positions a...

Page 6: ...e flow control Switch 2 Enable Disable the LED Indicator The setting for Switch 2 determines whether the LED indicator is enabled or disabled 5 Flow Control SW1 Hardware OFF Software ON LED SW2 ON ON...

Page 7: ...termine the frequency and data rate The following chart shows the settings that may be used 6 300 OFF OFF ON 600 ON OFF ON 1200 ON ON OFF 2400 OFF ON ON 4800 ON ON ON 9600 OFF OFF OFF 19200 ON OFF OFF...

Page 8: ...the DIP switches just plug it in like a normal cable and you re ready to go Figure 3 illustrates the proper connections for the standard cables If you have special ordered a non standard connector you...

Page 9: ...o indicate the condition of the transmission line Figure 1 shows the location of the LED The following chart describes the LED s various functions The red LED indicator blinks to show data activity Ho...

Page 10: ...gral cable Data Rates 0 38 400 Kbps LED LED displays status and operating condition Power Supply No external power required uses power from RS 232 interface Data Format 7 or 8 bits 1 or 2 stop bits ev...

Page 11: ...DB 9 Interface Strobe Output 1 Data bit 0 I O 2 Data bit 1 I O 3 Data bit 2 I O 4 Data bit 3 I O 5 Data bit 4 I O 6 Data bit 5 I O 7 Data bit 6 I O 8 Data bit 7 I O 9 Acknowledge Input active low 10 B...

Page 12: ...An Certi APPENDIX C PATTON MODEL 2029 BLOCK DIAGRAM Copyright Patton Electronics Company All Rights Reserved 11...

Reviews: