background image

APPENDIX B

PATTON MODEL 2029 INTERFACE CONNECTIONS

10

1- Carrier Detect (CD)
2- Receive Data (RD)
3- Transmit Data (TD)
4- Data Terminal Ready (DTR)
5- Signal Ground/ Frame Ground

(SG/ FG)

Data Set Ready (DSR) - 6

Ready to Send (RTS) - 7

Clear to Send (CTS) - 8

External Power - 9

Model 2029  DB-9 Interface

Strobe (Output)-1

Data bit 0 (I/O)-2
Data bit 1 (I/O)-3
Data bit 2 (I/O)-4
Data bit 3 (I/O)-5
Data bit 4 (I/O)-6
Data bit 5 (I/O)-7
Data bit 6 (I/O)-8
Data bit 7 (I/O)-9

Acknowledge (Input - active low)-10

Busy (Input - active high)-11

Paper End-12

Select-13

14

No Connect-15

16
17

+5 volts-18

19-Ground 
20-Ground 
21-Ground 
22-Ground 
23-Ground 
24-Ground 
25-Ground 
26-Ground 
27-Ground 
28-Ground 
29-Ground 
30-Ground 
31
32-Error 
33-Ground 
34
35
36-Ground 

Model 2029  Centronics

APPENDIX A

PATTON MODEL 2029 SPECIFICATIONS

Interface:  

Asynchronous., RS-232C compatible

Connectors:

Serial, DB-9 female; Parallel, Centronics 
male

Cables:

Six foot integral cable 

Data Rates:

0- 38,400 Kbps

LED:  

LED displays status and operating condition

Power Supply: 

No external power required; uses power 
from RS-232 interface

Data Format: 

7 or 8 bits; 1 or 2 stop bits; even, odd or no 
parity

Temperature Range: 0-60

°

C (32-140

°

F)

Altitude:  

0-10,100 feet

Humidity:  

5 to 95% non-condensing

Dimensions:  

2.68” x 1.25” x .75”

Weight:  

2 oz.  (56.8 grams)

9

Summary of Contents for 2029

Page 1: ...lel to Serial Serial to Parallel Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2029 B Rev C Doc 102011UB Revised 6 16 09 C E R T I F I E D An...

Page 2: ...d used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 2029 has been tested and found to comply with the l...

Page 3: ...ontainer This number may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted...

Page 4: ...S A 2 2 DESCRIPTION The Patton Model 2029 Parallel to Serial Converter automatically converts RS 232C serial data to parallel data format and vice versa Incorporating advanced microprocessor technolo...

Page 5: ...open the case for configuration The configuration switches allow you to select data rates parity word length and flow control selection The following section describes all switch locations positions a...

Page 6: ...e flow control Switch 2 Enable Disable the LED Indicator The setting for Switch 2 determines whether the LED indicator is enabled or disabled 5 Flow Control SW1 Hardware OFF Software ON LED SW2 ON ON...

Page 7: ...termine the frequency and data rate The following chart shows the settings that may be used 6 300 OFF OFF ON 600 ON OFF ON 1200 ON ON OFF 2400 OFF ON ON 4800 ON ON ON 9600 OFF OFF OFF 19200 ON OFF OFF...

Page 8: ...the DIP switches just plug it in like a normal cable and you re ready to go Figure 3 illustrates the proper connections for the standard cables If you have special ordered a non standard connector you...

Page 9: ...o indicate the condition of the transmission line Figure 1 shows the location of the LED The following chart describes the LED s various functions The red LED indicator blinks to show data activity Ho...

Page 10: ...gral cable Data Rates 0 38 400 Kbps LED LED displays status and operating condition Power Supply No external power required uses power from RS 232 interface Data Format 7 or 8 bits 1 or 2 stop bits ev...

Page 11: ...DB 9 Interface Strobe Output 1 Data bit 0 I O 2 Data bit 1 I O 3 Data bit 2 I O 4 Data bit 3 I O 5 Data bit 4 I O 6 Data bit 5 I O 7 Data bit 6 I O 8 Data bit 7 I O 9 Acknowledge Input active low 10 B...

Page 12: ...An Certi APPENDIX C PATTON MODEL 2029 BLOCK DIAGRAM Copyright Patton Electronics Company All Rights Reserved 11...

Reviews: