background image

1.0  WARRANTY INFORMATION 

Patton Electronics warrants all Model 2029 components to be

free from defects, and will—at our option—repair or replace the product
should it fail within one year from the first date of shipment.

This warranty is limited to defects in workmanship or materials,

and does not cover customer damage, abuse or unauthorized
modification.  If this product fails or does not perform as warranted,
your sole recourse shall be repair or replacement as described above.
Under no condition shall Patton Electronics be liable for any damages
incurred by the use of this product.  These damages include, but are
not limited to, the following:  lost profits, lost savings and incidental or
consequential damages arising from the use of or inability to use this
product.  Patton Electronics specifically disclaims all other warranties,
expressed or implied, and the installation or use of this product shall be
deemed an acceptance of these terms by the user. 

1.1  RADIO AND TV INTERFERENCE

The Model 2029 generates and uses radio frequency energy, and

if not installed and used properly—that is, in strict accordance with the
manufacturer's instructions—may cause interference to radio and
television reception.  The Model 2029 has been tested and found to
comply with the limits for a Class A computing device in accordance
with the specifications in Subpart J of Part 15 of FCC rules, which are
designed to provide reasonable protection from such interference in a
commercial installation.  However, there is no guarantee that
interference will not occur in a particular installation.  If the Model 2029
does cause interference to radio or television reception, which can be
determined by disconnecting the RS-232 interface, the user is
encouraged to try to correct the interference by one or more of the
following measures:  moving the computing equipment away from the
receiver, re-orienting the receiving antenna and/or plugging the
receiving equipment into a different AC outlet (such that the computing
equipment and receiver are on different branches).

1.2 CE NOTICE

The CE symbol on your Patton Electronics equipment indicates

that it is in compliance with the Electromagnetic Compatibility (EMC)
directive and the Low Voltage Directive (LVD) of the Union European
(EU).  A Certificate of Compliance is available by contacting Technical
Support.

1

1.3 SERVICE

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics.  All returns must have a
Return Materials Authorization number on the outside of the shipping
container. This number may be obtained from Patton Electronics
Technical Support: (301) 975-1007http://www.patton.com; or,
[email protected].

NOTE:  Packages received without an RMA number will not be

accepted.

Patton Electronics' technical staff is also available to answer any

questions that might arise concerning the installation or use of your
Model 2029.  Technical Support hours:  8AM to 5PM EST, Monday
through Friday.

2

Summary of Contents for 2029

Page 1: ...lel to Serial Serial to Parallel Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2029 B Rev C Doc 102011UB Revised 6 16 09 C E R T I F I E D An...

Page 2: ...d used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 2029 has been tested and found to comply with the l...

Page 3: ...ontainer This number may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted...

Page 4: ...S A 2 2 DESCRIPTION The Patton Model 2029 Parallel to Serial Converter automatically converts RS 232C serial data to parallel data format and vice versa Incorporating advanced microprocessor technolo...

Page 5: ...open the case for configuration The configuration switches allow you to select data rates parity word length and flow control selection The following section describes all switch locations positions a...

Page 6: ...e flow control Switch 2 Enable Disable the LED Indicator The setting for Switch 2 determines whether the LED indicator is enabled or disabled 5 Flow Control SW1 Hardware OFF Software ON LED SW2 ON ON...

Page 7: ...termine the frequency and data rate The following chart shows the settings that may be used 6 300 OFF OFF ON 600 ON OFF ON 1200 ON ON OFF 2400 OFF ON ON 4800 ON ON ON 9600 OFF OFF OFF 19200 ON OFF OFF...

Page 8: ...the DIP switches just plug it in like a normal cable and you re ready to go Figure 3 illustrates the proper connections for the standard cables If you have special ordered a non standard connector you...

Page 9: ...o indicate the condition of the transmission line Figure 1 shows the location of the LED The following chart describes the LED s various functions The red LED indicator blinks to show data activity Ho...

Page 10: ...gral cable Data Rates 0 38 400 Kbps LED LED displays status and operating condition Power Supply No external power required uses power from RS 232 interface Data Format 7 or 8 bits 1 or 2 stop bits ev...

Page 11: ...DB 9 Interface Strobe Output 1 Data bit 0 I O 2 Data bit 1 I O 3 Data bit 2 I O 4 Data bit 3 I O 5 Data bit 4 I O 6 Data bit 5 I O 7 Data bit 6 I O 8 Data bit 7 I O 9 Acknowledge Input active low 10 B...

Page 12: ...An Certi APPENDIX C PATTON MODEL 2029 BLOCK DIAGRAM Copyright Patton Electronics Company All Rights Reserved 11...

Reviews: