-4-
INSTRUCTIONS
SETUP
1.
Place the air scrubber so that it is in the upright, vertical position.
2.
Plug the machine into a standard 120 volt outlet.
Note: Each unit needs 3 amps to operate.
3.
Power the unit on and adjust the speed by turning the variable speed control. The maximum
speed is 550 CFM and the minimum speed is 280 CFM.
4.
The air scrubber can be operated in the vertical or horizontal position, depending on the exact
situation. At this point, adjust the machine to the optimal position.
THE CONTROL PANEL
Variable Speed Control
Variable speed control is used to adjust the power of the machine.Turn the knob in a clockwise
direction, to increase the speed from minimum speed to maximum, the minimum speed setting is
located immediately close to OFF.
Auxiliary Outlet
If more air filtration is necessary for a space, you can "daisy chain" or link up to 3 air scrubber to the
same outlet. There is a maximum amperage of 12 when the units are turned off, a maximum of 9 amps
when the units are turned on. Other equipment can be plugged into the same outlet as the air
scrubber as long as it doesn't go above the max amperage.
Circuit Breaker Switch
The Circuit Breaker Switch protects the unit if there are more than 12 amps of electricity passing the
circuit. If this occurs, the switch will cut off the power to the unit.
Timer
Used to time the running time of the device. Start timing when the device is running, and pause timing
when the device is stopped.
Power cord
Cord Wrap
Retaining Clips
(4 on base)
Removeable plastic
Motor
Control Panel
Retaining Clips
(4 on base)
5.
When the machine total working time up to 2000 hours, the filter change warning light will blink
with buzzing on control panel to remind changing filters.(To reset the machine, need to push
the UV-C light switch 3 times continuously in 5 seconds to Reset the filter service time).
6.
UV-C sterilization lamp fault detection function: when the UV-C sterilization lamp does not work,
the buzzer will keep ringing.